AERASGARD® RFTM-PS-CO2

Product group: WG02

Low availability.

Usually ships in 3 to 5 days
$ 1,473.02
$ 1.237,83 + sales tax + shipping
+

Description

AERASGARD®
Maintenance-free, multifunctional AERASGARD® RFTM - PS - CO2 - W room air quality measuring transducer with active/switching output, automatic calibration, in an elegant plastic housing with snap-on cover, base with 4-hole attachment, optionally with/without display, for detecting air humidity (0...100% RH), temperature (0...+50°C), particulate matter (PM) (0...50/100/300/500 μg/m3) and CO2 content (0...2000 / 5000 ppm). The transmitter converts the measured values into a standard signal of 0-10 V or 4...20 mA (switchable).

The multifunctional sensor device is ideal for effectively monitoring and controlling the entire indoor climate with just one device. This enables energy-saving room ventilation on an as-needed basis, thereby reducing operating costs and improving well-being. It is used in offices, hotels, convention centres, apartments, shops, etc.
A long-term stable, digital humidity and temperature sensor guarantees precise measuring results. The CO2 content of the air is measured using an optical NDIR sensor (non-dispersive infra-red technology). An optical particulate sensor precisely detects particulate matter (PM) of size categories 0.3 to 10 micrometres. The sensor is factory-calibrated and can be fine-tuned to ambient conditions by an expert.

Technical details

Long-term stability (PM)
± 1.25 μg/m3 (± 1.25 % of measured value/year)
Measuring accuracy (PM)
typically ± 10 μg/m3 (± 10 % of measured value) at PM 2.5
typically ± 25 μg/m3 (± 25 % of measured value) at PM 10
Measuring range (PM)
0... 50 μg/m³ 0...100 μg/m³ 0...300 μg/m³ 0...500 μg/m³
Particle size (PM)
PM 2,5 (0,3...2,5 μm); PM 10 (0,3...10 μm)
Voltage supply
24 V AC/ DC (± 10 %)
Power consumption
RFTM-PS-CO2-W: < 4.4 W/ 24 V DC typical; < 6.4 VA/ 24 V AC typical;
peak current 200 mA

Measuring range, humidity
0...100 % RH
Operating range, humidity
0...95 % RH (without dew formation)
Deviation of humidity
typical ± 2 % RH (20…80 % RH ); at + 77 °F, otherwise ± 3 %
Measuring range, temperature
0...+ 50 °C (output equivalent to 0 -10 V or 4...20 mA)
Operating range, temperature
32...+122 °F
Temperature deviation
typically ± 0.4 °F at +77 °F
Relay output
with potential-free changeover contact (24 V / 1 A)
(assignment selectable via DIP switches, switchpoint adjustable)
Output
0 -10 V or 4...20 mA (selectable via DIP switches,
selected variant applies for all outputs), working resistance < 800 Ω
Measuring range
0...50 / 0...100 / 0...300 / 0...500 μg/m³
Ambient temperature
32...+122 °F
Electrical connection
AWG 16 - 26 via terminal screws

Housing
plastic, material ABS,
colour pure white (similar to RAL 9010)
Dimensions
3.86 x 3.86 x 1.30 in (Baldur 2)
Installation
wall mounting or on in-wall flush box, Ø 2.2 in,
base with 4 holes, for attachment to vertically or
horizontally installed in-wall flush boxes for rear cable entry,
with predetermined breaking point for cable entry
from top/ bottom in case of plain on-wall installation
Protection class
III (according to EN 60 730)
Protection type
IP 30 (according to EN 60 529)
Protection type housing
IP 30
Standards
CE conformity, electromagnetic compatibility
according to EN 61 326, EMC Directive 2014/ 30/ EU,
Low Voltage Directive 2014/ 35/ EU