- New
- Sale
- Temperature
- Humidity
- Pressure
- Light Intensity & Motion
- Air Quality
- Flow
- Modbus | Wireless Modbus
- Room controller
- EtherCAT P
- Accessory
Description
Room air quality sensor (VOC) and measuring transducer
AERASGARD® RLQ-W VA
Maintenance-free AERASGARD® RLQ - SD room air quality transmitter with active output, automatic calibration (fixed), in an elegant plastic housing with snap-on cover, for determining the air quality in three VOC sensitivity levels (low/medium/high). The measuring transducer converts the measured values into a standard signal of 0-10 V or 4...20 mA (switchable).
Maintenance-free AERASGARD® RLQ - W room air quality transmitter with active/switching output, automatic calibration (can be deactivated), in an elegant plastic housing with snap-on cover, optional with traffic light indicator (five coloured LEDs), for determining the air quality in three VOC sensitivity levels (low/ medium/high). The measuring transducer converts the measured values into a standard signal of 0-10 V or 4...20 mA (switchable).
The sensor device device is used in offices, hotels, convention centres, apartments, shops, etc. for the purpose of evaluating the indoor climate. This enables energy-saving room ventilation on an as-needed basis, thereby reducing operating costs and improving well-being.
The air quality is detected by a VOC sensor (mixed gas sensor for volatile organic substances). This sensor determines the load of contaminated gases in the room air, such as from cigarette smoke, body perspiration, exhaled breathing air, solvent vapours, emissions from building components, etc. Low, medium or high VOC sensitivity can be selected depending on the expected air contamination.
The sensor device device is used in offices, hotels, convention centres, apartments, shops, etc. for the purpose of evaluating the indoor climate. This enables energy-saving room ventilation on an as-needed basis, thereby reducing operating costs and improving well-being.
The air quality is detected by a VOC sensor (mixed gas sensor for volatile organic substances). This sensor determines the load of contaminated gases in the room air, such as from cigarette smoke, body perspiration, exhaled breathing air, solvent vapours, emissions from building components, etc. Low, medium or high VOC sensitivity can be selected depending on the expected air contamination.
Technical details
Voltage supply
24 V AC/ DC (± 10 %)
Power consumption
< 1.5 W/ 24 V DC typical;
< 2.9 VA/ 24 V AC typical;
peak current 200 mA
< 2.9 VA/ 24 V AC typical;
peak current 200 mA
Data points
Air quality (VOC)
Measuring range, VOC
0...100 % Air quality - VOC sensitivities (low/medium/high)
Service life
> 60 months (under normal load conditions),
depending on the type of loading and gas concentration
depending on the type of loading and gas concentration
Measuring accuracy
± 20 % of final value (referred to calibrating gas)
Gas exchange
by diffusion
Relay output
with potential-free changeover contact (24 V / 1 A)
(switchpoint can be adjusted from 0...100 % of the output signal)
(switchpoint can be adjusted from 0...100 % of the output signal)
Warm up time
approx. 1 hour
Response time
approx. 1 minute
Output
(0 V = clean air, 10 V = polluted air)
0 -10 V or 4...20 mA, working resistance < 800 Ω
(selectable via DIP switches)
with offset potentiometer (± 10 % of the measuring range
0 -10 V or 4...20 mA, working resistance < 800 Ω
(selectable via DIP switches)
with offset potentiometer (± 10 % of the measuring range
Sensor
VOC sensor (metal oxide) (VOC = volatile organic compounds),
with manual calibration (via zero button),
with automatic calibration (can be deactivated via DIP switches)
with manual calibration (via zero button),
with automatic calibration (can be deactivated via DIP switches)
Measuring range
0...100 % air quality; referred to calibrating gas;
multi-range switching (selectable via DIP switches)
VOC sensitivity low, medium, high
multi-range switching (selectable via DIP switches)
VOC sensitivity low, medium, high
Ambient temperature
+32...+122 °F
Electrical connection
AWG 16 - 26 via terminal screws
Housing
stainless steel V2A (1.4301)
Housing dimensions
100 x 100 x 25 mm (stainless steel enclosure)
Installation
wall mounting or on in-wall flush box, Ø 2.2 in,
base with 4 holes, for attachment to vertically or
horizontally installed in-wall flush boxes for rear cable entry,
with predetermined breaking point for cable entry
from top/ bottom in case of plain on-wall installation
base with 4 holes, for attachment to vertically or
horizontally installed in-wall flush boxes for rear cable entry,
with predetermined breaking point for cable entry
from top/ bottom in case of plain on-wall installation
Protection class
III (according to EN 60 730)
Protection type
IP 30 (according to EN 60 529)
Protection type housing
IP 30
Standards
CE conformity, electromagnetic compatibility
according to EN 61 326, EMC Directive 2014/ 30/ EU,
Low Voltage Directive 2014/ 35/ EU
according to EN 61 326, EMC Directive 2014/ 30/ EU,
Low Voltage Directive 2014/ 35/ EU