Description
room control unit
RYMASKON® 700
The RYMASKON® 500 / 600 / 700 series of room control units has been designed for controlling climate zones in residential, hotel and office rooms and individually regulating the heating/cooling steps of interior spaces. A colour touch display with modern icons is used for visual display and operation on site. The product range is characterised by the versatile combination possibilities of the individual components.
The RYMASKON® 700 Interface series can be used for bus-based control of heating or cooling valves, fan speed and solar protection equipment (shutters, Venetian blinds) in two zones. Two external temperature sensors (NTC10K) can be connected in addition to the integrated temperature sensor. Measuring elements for relative humidity and CO2 are also available. The devices are used in room climate engineering, including convector fans, cooling ceilings and heating/cooling systems. Wall mounting is performed on standard in-wall flush boxes. The controllers are optionally available with a Modbus or BACnet communication interface and in various type versions (see number key).
The RYMASKON® 710 Interface basic model has a colour touch display (3.5") in a white housing, an integrated temperature and humidity sensor (CO2 sensor optional), 2 resistance inputs (NTC10K) for external sensors, 1 digital input, 1 relay output (7 A / 0.5 A with CO2) and an optional Modbus or BACnet interface. The room control units are mainly used for controlling temperature, fans and solar protection (2 zones) via fieldbus.
The RYMASKON® 710 Interface basic model has a colour touch display (3.5") in a white housing, an integrated temperature and humidity sensor (CO2 sensor optional), 2 resistance inputs (NTC10K) for external sensors, 1 digital input, 1 relay output (7 A / 0.5 A with CO2) and an optional Modbus or BACnet interface. The room control units are mainly used for controlling temperature, fans and solar protection (2 zones) via fieldbus.
Technical details
Voltage supply
24 V AC/DC (± 15 %)
Power consumption
max. 1.92 W
Measuring range, humidity
0...100 % r. H.
Deviation of humidity
typically ±2 % r.H. (20...80 % r.H.) at +25 °C
Measuring range, temperature
–40...+125 °C
Temperature deviation
typically ±0.5 °C at +25 °C
Temperature sensor
integrated temperature sensor
Inputs
2 resistance inputs (NTC10K) for external temperature sensors
1 digital input (potential-free), impedance <1 kOhm
1 digital input (potential-free), impedance <1 kOhm
Operating mode
Comfort, ECO, OFF, Boost
Operating elements
3.5" touch display with backlighting,
cut-out approx. 50 x 75 mm, resolution 320 x 480 pixels, 255,000 colours
cut-out approx. 50 x 75 mm, resolution 320 x 480 pixels, 255,000 colours
Communication
Modbus RTU Slave
address range can be configured between 1...247 or
BACnet MS/TP
device ID 65100 (default) and MAC address can be configured between 1..127
RS 485 interface, max. 63 devices,
9600 / 19200 / 38400 / 57500 / 76800 Baud,
none / even / odd parity, 1 / 2 stop bits
address range can be configured between 1...247 or
BACnet MS/TP
device ID 65100 (default) and MAC address can be configured between 1..127
RS 485 interface, max. 63 devices,
9600 / 19200 / 38400 / 57500 / 76800 Baud,
none / even / odd parity, 1 / 2 stop bits
Ambient temperature
0...+50 °C (operation); –30...+70 °C (storage)
Electrical connection
0.14 - 1.5 mm² via terminal screws
Housing
plastic, polycarbonate material, self-extinguishing,
white colour (optionally black or chrome), weight approx. 220g
Installation
wall mounting or on in-wall flush box, Ø 55 mm
Permissible air humidity
0...95 % r. H., (non-precipitating air)
Protection type
IP 20 (according to EN 60 529)
Standards
CE conformity,
according to EMC directive 2004/108/EU, Low-Voltage directive 2006/95/EU,
according to EN 61000-6-1/3, EN 60730-1, EN 6100-4-2/4/5/11
according to EMC directive 2004/108/EU, Low-Voltage directive 2006/95/EU,
according to EN 61000-6-1/3, EN 60730-1, EN 6100-4-2/4/5/11
Function
temperature and fans (1 zone),
sun protection hood (2 zones),
Air conditioning (1 zone),
light (1 zone)
sun protection hood (2 zones),
Air conditioning (1 zone),
light (1 zone)