- New
- Sale
- Temperature
- Humidity
- Pressure
- Light Intensity & Motion
- Air Quality
- Flow
- Modbus | Wireless Modbus
- Room controller
- EtherCAT P
- Accessory
Description
Pendulum room temperature measuring transducer
THERMASGARD® RPTM1
Calibratable THERMASGARD® RPTM 1 room pendulum temperature measuring transducer (with sleeve) with eight switchable measuring ranges, continuous output, in an impact resistant plastic housing with quick-locking screws, optionally with/without display, cable sensor with stainless steel sleeve and plastic sinter filter (exchangeable).
The pendulum sensor device has been specially designed to detect the temperature in larger rooms or halls. The resistance thermometre achieves a very good, representative measurement result due to its positioning in the room. The sensor is factory-calibrated and can be fine-tuned to ambient conditions by an expert.
Technical details
Power consumption
< 1,0 W/ 24 V DC
< 2,2 VA/ 24 V AC
< 2,2 VA/ 24 V AC
Sensor
Pt1000, DIN EN 60751, class B
Connection type
2- or 3-wire connection
Measuring ranges
multi-range switching with 8 switchable measuring ranges
(other ranges optional) Tmin –5 °C, Tmax +60 °C
with manual zero point correction (± 10 K)
(other ranges optional) Tmin –5 °C, Tmax +60 °C
with manual zero point correction (± 10 K)
Accuracy
typically ± 0.4 °F at +77 °F
Ambient temperature
measuring transducer –5...+60 °C
Connection cable
PVC; LiYY, 1.5 m
(other lengths optional: e.g. 3 m, 6 m)
(other lengths optional: e.g. 3 m, 6 m)
Protective tube
stainless steelV2A (1.4301), Ø = 0.63 in, L = 5.59 in
Electrical connection
AWG 16 - 26 via terminal screws
Cable connection
cable gland, plastic (M 16 x 1.5; with strain relief, exchangeable, max. inner diameter 0.4 in) or
M12 connector according to DIN EN 61076-2-101 (optional on request)
M12 connector according to DIN EN 61076-2-101 (optional on request)
Cable gland
M 16 x 1.5, including strain relief, exchangeable,
max. inner diameter 0.4 in
max. inner diameter 0.4 in
sensor cable
PVC, H03VV-F, 2 x 21 AWG,
KL = approx. 5 ft (other lengths optional)
KL = approx. 5 ft (other lengths optional)
Humidity
< 95 % RH, non-precipitating air
Protection class
III (according to EN 60 730)
Protection type
IP 65 (according to EN 60 529) Housing tested,
TÜV SÜD, Report No.713139052 (Tyr 1)
TÜV SÜD, Report No.713139052 (Tyr 1)
Standards
CE conformity,
electromagnetic compatibility according to EN 61326,
according to EMC Directive 2014/ 30/ EU
electromagnetic compatibility according to EN 61326,
according to EMC Directive 2014/ 30/ EU