Efficiënt, koppelbaar en comfortabel

Elegant uiterlijk, aanraakoppervlak, groot display, voor Modbus-geschikt

RYMaskon

Plugs in perfectly!

Humidity and temperature measuring transducer for installation in showcases and display cabinets.

HYGRASGARD® VFF ⁄ VFTF

Compact, piezo-precise and cost-efficient - Specialists in pressure

Multi-range measuring transducers for pressure, differential pressure and volume flow

PREMASGARD 111x, 112x and 112x-SD

Pluggable and elegant

In-Ceiling Sensors now also for humidity and light intensity

THERMASGARD® DTF

Für jede Anwendung die richtige Lösung

KAVTF-I DISPLAY

HYGRASGARD® KAVTF-I DISPLAY

Art.nr. 1201-3162-6200-029
EAN 4 251325 610474

De universele vochtsensors HYGRASGARD® KAVTF met 6 uitgangsgrootten dienen voor het vaststellen van diverse meetgrootheden in de vochtigheidsmeettechniek. De relatieve vochtigheid en de temperatuur van de omgevingslucht worden gemeten. Vanuit deze meetgrootheden worden intern verschillende karakteristieke grootheden berekend.

Bij apparaatversie x - U zijn twee uitgangen 0 - 10 V beschikbaar, bij versie x - I twee uitgangen 4...20 mA. Hierbij kunnen via DIP - schakelaars de uitgangsgrootten voor de uitgangen worden vastgelegd. Voor uitgang 1 kunnen worden gekozen relatieve vochtigheid [% r. h.], absolute vochtigheid [g ⁄ m³], mengverhouding [g ⁄ kg], dauwpunttemperatuur [°C] of enthalpie [kJ ⁄ kg] (met veronachtzaming van de atm. luchtdruk). Bij uitgang 2 kunnen vier verschillende meetbereiken voor de omgevingstemperatuur [°C] worden gekozen. De leveringsstatus voor uitgang 1 is de relatieve vochtigheid 0...100 % r.H., voor uitgang 2 het temperatuurmeetbereik 0...+50 °C. Door de verschillende configuratiemogelijkheden kunnen talrijke regeltaken door slechts één apparaat worden opgelost.

De apparaten moeten in niet condenserende lucht zonder schadelijke stoffen zonder onder- c.q. overdruk bij de sensoriek worden gebruikt. Toepassingsgebieden zijn bv. de medische techniek, de koeltechniek, de klimaat- en cleanroom-techniek. De voelers zijn geschikt voor de kanaalmontage.

209,10 € netto
Voltage supply 15...36 V DC
depending on working resistance, residual ripple stabilised ± 0.3 V
Power consumption < 1 W at 24 V DC; < 2 VA at 24 V AC
Working resistance Ra (ohm) = (Ub -14 V) ⁄ 0.02 A for I variant
Sensors digital humidity sensor
with integrated temperature sensor,

low hysteresis, high long-term stability
Measuring range, humidity multi-range switching with 8 switchable measuring ranges
0...100 % r. H. (standard)
Operating range, humidity 10...95 % r. H., without formation of dew
Deviation of humidity typical ± 2 % r. H. (20…80 % r. H. ); at + 25 °C, otherwise ± 3 % r. H.
Deviations of other outputs result from
deviations of humidity and temperature.
Output, humidity 4...20 mA
Measuring range, temperature multi-range switching with
4 switchable measuring ranges
0...+50 °C (standard); –20...+80 °C; –35...+75 °C; –35...+35 °C
Operating range, temperature –35...+85 °C sensors
Temperature deviation ± 0.2 K at +25 °C
Output, temperature 4...20 mA
Sensor protection plastic sinter filter, Ø 16 mm, L = 35 mm, exchangeable
(optional metal sinter filter, Ø 16 mm, L = 32 mm)
Ambient temperature storage –35...+85 °C,
operation – 30...+70 °C, non-precipitating
Process connection by mounting flange, plastic
(included in the scope of delivery)
Protective tube PLEUROFORMTM, material polyamide (PA6), with torsion
protection, Ø 20 mm, NL = 235 mm, vmax = 30 m/s (air)
(on request, optional stainless steel, Ø 16 mm)
Electrical connection 3-wire connection (Transmitter)
0.14 - 1.5 mm², via terminal screws on circuit board
Enclosure plastic, UV-stabilised,
material polyamide, 30 % glass-globe reinforced,
with quick-locking screws
(slotted ⁄ Phillips head - combination),
colour traffic white (similar to RAL 9016),
enclosure cover for display is transparent !
Enclosure dimensions 72 x 64 x 43.3 mm (Tyr 1 with Display)
Cable gland 2x M 12 x 1.5 (Y-adapter); with strain relief,
exchangeable, max. inner diameter 6 mm
Protection class III (according to EN 60 730)
Protection type IP 65 (according to EN 60 529) enclosure only!
Standards CE conformity,
electromagnetic compatibility according to EN 61326,
according to EMC Directive 2014 ⁄ 30 ⁄ EU
Optional two-line display with illumination, 36 x15 mm (W x H),
for displaying ACTUAL temperature and ⁄ or ACTUAL humidity

S+S Regeltechnik - voordelen tot de vijfde macht

Meer te weten komen

Nieuws van S+S Regeltechnik

BeursnieuwsAlle aangeven

 

SPS IPC Drives – S+S Regeltechnik will be there
27. - 29.11.2018

Booth 10.1-120
Be our guest at Europe's leading trade fair for electric automation from 27 to...
meer

 

S+S Regeltechnik at CHILLVENTA 2018
16. - 18.10.2018

Booth 5-305
We are pleased to return and exhibit again at CHILLVENTA this fall. As...
meer

Overzicht van alle beursdata

ProductnieuwsAlle aangeven

 

HYGRASGARD® VFF ⁄ VFTF - Humidity and temperature measuring transducer for installation in showcases and display cabinets

This new device from S+S measures temperature and humidity using a digital sensor designed for...
meer

 

Good room climate is measurable – AERASGARD® RCO2-SD und KCO2-SD

With immediate effect, our room and duct sensors for measuring the CO2 concentration in air are now...
meer

Beursnieuws

NordBygg 2018 | 10.04. - 13.04.2018 | Booth A30:02

meer

Abonneren op Newsletter

Blijf altijd geïnformeerd over onze producten en nieuws rond S+S Regeltechnik.