Efficiënt, koppelbaar en comfortabel

Elegant uiterlijk, aanraakoppervlak, groot display, voor Modbus-geschikt

RYMaskon

Good room climate is measurable!

Active and Modbus capable room sensors for temperature, humidity and CO2 now also for in-wall installation!

AERASGARD® FSCO2

All quite relative

Pressure measuring transducer for gaseous and liquid media in cost-efficient Standard version for 0 to 16 bar

PREMASGARD® SHD-SD

VOC in focus

Room and duct sensors for detection of mixed gases in cost-efficient Standard versions

AERASGARD® RLQ-SD

Für jede Anwendung die richtige Lösung

KFTM-CO2 MODBUS

AERASGARD® KFTM-CO2 MODBUS

Art.nr. 1501-8116-6001-200
EAN 4 251325 615554

Patentiertes Qualitätsprodukt (Patent-Nr. DE 10 2014 010 719.1)

Der wartungsfreie mikroprozessorgesteuerte AERASGARD® KFTM - LQ - CO2 - Modbus bzw. KCO2 - Modbus ⁄ KLQ - CO2 - Modbus mit Modbus-Anschluss, wahlweise mit ⁄ ohne Display, ist zur Kanalmontage und dient zur Erfassung aller für ein Raumklima relevanten Messgrößen. Hierzu werden die Messgrößen Luftfeuchtigkeit, Temperatur, CO2 Konzentration sowie Luftqualität (VOC) gemessen. Durch Erfassung aller vier Messgrößen in einem Gerät kann das gesamte Raumklima effektiv überwacht und gesteuert werden. Er misst CO2 im Bereich von 0...5000 ppm, VOC in einer von drei wählbaren Sensibilitätsstufen LOW / MEDIUM / HIGH, Temperaturen im Bereich von –35...+80 °C sowie die relative Luftfeuchtigkeit von 0...100 % r.H.

Die relative Feuchte (% r.H.) ist der Quotient aus dem Wasserdampfpartialdruck und dem Sättigungsdampfdruck bei der jeweiligen Gastemperatur. Ein digitaler, langzeitstabiler Sensor als Messelement für relative Luftfeuchte und Temperatur garantiert exakte Messergebnisse.

Der CO2Gehalt der Luft wird mittels optischen NDIR-Sensors (nicht-dispersive Infrarot-Technologie) ermittelt. Der Erfassungsbereich der Sensoren wird auf Standardanwendungen wie z. B. Wohn und Tagungsraum überwachung kalibriert. Bedarfsgerechte Lüftung, Steigerung des Wohlbefindens und des Kundennutzens, erhöhter Komfort sowie eine Senkung der Betriebskosten durch Energieeinsparung sind nur einige Ergebnisse des Einsatzes des AERASGARD® CO2.

Obige Ausführungen zeigen, dass es Anwendungen für CO2-Messungen, Anwendungen für VOC-Messungen aber aus unserer Sicht vorrangig Anwendungen für die Kombination bei der Messgrößen gibt. Wichtig hierbei ist, dass sich diese beiden Messgrößen nicht ineinander umrechnen bzw. Ableitungen zueinander herstellen lassen. Ein NDIR-CO2 Messgerät misst selektiv kann keine VOCs detektieren, ein VOC-Mischgassensor kann keine CO2 Moleküle erfassen.

334,56 € netto
Voltage supply 24 V AC ⁄ DC (± 10 %)
Power consumption < 4.4 W ⁄ 24 V DC typical; < 6.4 VA ⁄ 24 V AC typical;
peak current 200 mA
Data points temperature, relative humidity,
air quality (VOC), carbon dioxide (CO2),
atmospheric pressure
Sensors digital humidity sensor
with integrated temperature sensor,

low hysteresis, high long-term stability
Measuring range, humidity 0...100 % r. H.
Operating range, humidity 0...95 % r. H. (without dew formation)
Deviation of humidity typical ± 2 % r. H. (20…80 % r. H. ); at + 25 °C, otherwise ± 3 % r. H.
Measuring range, temperature –35...+80 °C
Operating range, temperature –10...+60 °C
Temperature deviation ± 0.2 K at +25 °C
Measuring range, CO2 0...5000 ppm
Sensor, CO2 optical NDIR sensor (non-dispersive infra-red technology)
including atmospheric pressure compensation (up to 1100 mbar)
with automatic and manual calibration
Measuring accuracy, CO2 ± 30 ppm ± 3 % of measured value
Temperature dependence, CO2 ± 5 ppm ⁄ °C or ± 0.5 % of measured value ⁄ °C
(whichever is higher)
Pressure dependence ± 0,13 % ⁄ mm Hg
Gas exchange by diffusion
Response time < 2 minutes
Sensor protection plastic sinter filter, Ø 16 mm, L = 35 mm, exchangeable
(optional metal sinter filter, Ø 16 mm, L = 32 mm)
Ambient temperature –10...+60 °C
Bus protocol Modbus (RTU mode),
address range 0...247 selectable
Signal filtering 4 s / 32 s
Process connection by mounting flange, plastic
(included in the scope of delivery)
Protective tube PLEUROFORMTM, material polyamide (PA6), with torsion protection, Ø 20 mm, vmax = 30 m/s (air)
without filter: NL = 202.5 mm / with plastic filter: NL = 235 mm (optional with metal filter: NL = 227 mm)
Electrical connection 0.14 - 1.5 mm2, via push-in terminal
Enclosure plastic, UV-stabilised,
material polyamide, 30 % glass-globe reinforced,
with quick-locking screws
(slotted ⁄ Phillips head - combination),
colour traffic white (similar to RAL 9016)
Enclosure dimensions 126 x 90 x 50 mm (Tyr 2)
Cable gland 2x M 16 x 1.5; including strain relief, exchangeable
Long-term stability < 2 % in 15 years
Protection class III (according to EN 60 730)
Protection type IP 65 (according to EN 60 529) enclosure only! (PLEUROFORM IP 30)
Standards

CE-Konformitat, elektromagnetische
Vertraglichkeit nach EN 61326,
nach EMV-Richtlinie 2014 ⁄ 30 ⁄ EU

Type Art.nr. Prijs
KA-2 1906-1200-0000-100 0,00 €

S+S Regeltechnik - voordelen tot de vijfde macht

Meer te weten komen

Nieuws van S+S Regeltechnik

BeursnieuwsAlle aangeven

 

GET Nord - S+S Regeltechnik is er
22. - 24.11.2018

Stand B4.04.151
Wees onze gast op de internationale vakbeurs voor elektriciteit, sanitair,...
meer

 

SPS IPC Drives – S+S Regeltechnik will be there
27. - 29.11.2018

Booth 10.1-120
Be our guest at Europe's leading trade fair for electric automation from 27 to...
meer

Overzicht van alle beursdata

ProductnieuwsAlle aangeven

 

Multi-functional duct sensor for monitoring and control of heating, ventilation and air-conditioning systems

This bus capable and calibratable pressure measuring transducer enables the control of differential...
meer

 

Good room climate is measurable! - AERASGARD® FSCO2 ⁄ FSTM-CO2 ⁄ FSFTM-CO2-Modbus

Our multifunctional room sensors for measuring temperature, humidity and CO2 concentration can now...
meer

Beursnieuws

GET Nord | 22. - 24.11.2018 | Stand B4.04.151

meer