Efficiënt, koppelbaar en comfortabel

Elegant uiterlijk, aanraakoppervlak, groot display, voor Modbus-geschikt

RYMaskon

Good room climate is measurable!

Active and Modbus capable room sensors for temperature, humidity and CO2 now also for in-wall installation!

AERASGARD® FSCO2

All quite relative

Pressure measuring transducer for gaseous and liquid media in cost-efficient Standard version for 0 to 16 bar

PREMASGARD® SHD-SD

VOC in focus

Room and duct sensors for detection of mixed gases in cost-efficient Standard versions

AERASGARD® RLQ-SD

Für jede Anwendung die richtige Lösung

DBWF-LF-FTF-W

KINASGARD® DBWF-LF-FTF-W

Art.nr. 1401-6114-3100-000
EAN 4 251325 612959

De aanwezigheidsmelder, plafondinbouwvoeler KINASGARD® / PHOTASGARD® DBWF ⁄ LF ⁄ FTF dient ter registratie van personen op een afstand van maximaal 10 meter, van de lichtsterkte c.q. helderheid, de relatieve luchtvochtigheid en de temperatuur. Hij wordt gebruikt voor inbouw in verlaagde plafonds.

De sensor registreert bewegingen met een openingshoek van 110° en 360° omtrek. Door het gepatenteerde lenzensysteem met 20 losse lenzen ontstaan zeer kleine donkere gebieden, die ook op een afstand van 10 m slechts enkele centimeter groot zijn en kleine bewegingen op betrouwbare wijze registreren. Als een beweging wordt gedetecteerd, wordt de potentiaalvrije relaisuitgang geschakeld. De verblijftijd van de uitgang, gemeten vanaf het tijdstip van de laatst gedetecteerde beweging, kan in het apparaat via een potentiometer van 4 seconden tot ca. 17 minuten worden opgegeven.

Voor de temperatuur en vochtigheid is telkens een analoge uitgang 0 - 10 V overeenkomstig 0...+50 °C c.q. 0...100 % r. h. beschikbaar. Door inbouwlocatie en inbouwplaats veroorzaakte afwijkingen kunnen binnen het apparaat door telkens een offset-regelaar worden gecompenseerd.

Voor de Lichtsterkte c.q. helderheid van 0...1000 Lux of 0...5000 Lux (via DIP-schakelaars te kiezen) is eveneens een analoge uitgang 0 - 10 V beschikbaar. Bovendien is er via DIP-schakelaars de mogelijkheid om de bewegingsuitgang afhankelijk van de helderheid te activeren.

Toepassingsgebieden voor de DBWF ⁄ LF ⁄ FTF zijn de woonruimtebewaking, automatische lichtschakeling, regeltechniek, alarmtechniek en van beweging afhankelijke regeling van ruimtefuncties, bv. voor het verlagen van de temperatuur van ongebruikte ruimtes.

198,90 € netto
Voltage supply 24 V AC ⁄ DC
(half-wave rectification, read the instructions!)
Power consumption < 3.6 VA at 24 V DC
Measuring range, humidity 0...100 % r. H.
(output corresponding to 0 -10 V)
Operating range, humidity 10...95 % r. H., without formation of dew
Output, humidity 0 - 10 V
Measuring range, temperature 0...+ 50 °C
(output corresponding to 0 -10 V or 4... 20 mA or Ohm value)
others upon request!
Operating range, temperature 0...+50 °C
Temperature deviation ± 0.8 K at +20 °C, under standard conditions
Output, temperature 0 - 10 V
Output 0 -10 V or inverted 10 - 0 V (selectable via DIP switches)
Output, light sensor 0 - 10 V
Output, motion sensor potential-free changeover contact,
for switching safety extra-low voltage only, up to 1 A
Sensor infra-red motion sensor, light sensor with diffuser
Detection range perimeter 360°, aperture angle 90° ⁄ 110°,
reach approx. 10 m, circular, at an installation height of approx. 3 m
the sensor covers a detection radius (r) of approx. 3.4 m
Motion detection of persons and objects, required temperature difference
between subject and surroundings ≥ 5 K
After-running time adjustable from 4 s to 17 min
Sensor protection mounted inside ceiling installation housing
Measuring range, light sensor 0...1000 lux / 0...5000 lux (selectable via DIP switches)
Measuring error light sensor < ± 10 % of final value
(referred to calibration reference source, approx. 5700 K)
Ambient temperature 0...+50 °C
Storage temperature –20...+50 °C
Installation dimensions ceiling cutout: Ø 80 mm
installation depth: < 45 mm (incl. connector system)
on-wall protrusion: > 13 mm (motion sensor)
> 20 mm (humidity sensor)
Electrical connection 0.14 - 1.5 mm²
via terminal screws on circuit board
Enclosure steel, white painted
Enclosure dimensions cover: Ø 90 mm, height of enclosure: 30 mm
Temperature drift values < ± 5 % of final value ⁄ 10 K at +20 °C
Protection class III (according to EN 60 730)
Protection type {Reference (Object) not found: prod7768909658193}:

IP 20 (according to EN 60 529)

Standards CE conformity,
electromagnetic compatibility according to EN 61326,
according to EMC Directive 2014 ⁄ 30 ⁄ EU

S+S Regeltechnik - voordelen tot de vijfde macht

Meer te weten komen

Nieuws van S+S Regeltechnik

BeursnieuwsAlle aangeven

 

GET Nord - S+S Regeltechnik is er
22. - 24.11.2018

Stand B4.04.151
Wees onze gast op de internationale vakbeurs voor elektriciteit, sanitair,...
meer

 

SPS IPC Drives – S+S Regeltechnik will be there
27. - 29.11.2018

Booth 10.1-120
Be our guest at Europe's leading trade fair for electric automation from 27 to...
meer

Overzicht van alle beursdata

ProductnieuwsAlle aangeven

 

Multi-functional duct sensor for monitoring and control of heating, ventilation and air-conditioning systems

This bus capable and calibratable pressure measuring transducer enables the control of differential...
meer

 

Good room climate is measurable! - AERASGARD® FSCO2 ⁄ FSTM-CO2 ⁄ FSFTM-CO2-Modbus

Our multifunctional room sensors for measuring temperature, humidity and CO2 concentration can now...
meer

Beursnieuws

GET Nord | 22. - 24.11.2018 | Stand B4.04.151

meer

Abonneren op Newsletter

Blijf altijd geïnformeerd over onze producten en nieuws rond S+S Regeltechnik.