Construction progress of the Giga factory for sensor technology

The structural work on the production halls and offices at our new location in Nuremberg, Germany is nearing completion. Construction is progressing according to plan, so we are well positioned for the future and the increasing demand for our sensors.

Watch the video

Groundbreaking ceremony for significant growth

The office and manufacturing space alone at the new S+S location in Nuremberg will be expanded to 8,600 m² in order to meet the increasing demand for advanced sensor devices.

Watch the video

With Giga factory for sensors to become the #1 on the market

On a total area of over 14000 square meters, the new S+S company headquarters is being built in the north of Nuremberg.

Watch the video

Specialists in pressure

Multi-range measuring transducers for pressure, differential pressure and volume flow

PREMASGARD 211x / 212x

Efficient, convenient and network-enabled

Elegant appearance, touch-operated interface, large display, and Modbus-compatible

RYMaskon

Multi-funtional duct sensor

For humidity, temperature, pressure, differential pressure and volume flow for monitoring and controlling heating, ventilation and air-conditioning systems

PREMASGARD® 814x-Modbus

Satisfied customers drive our business

An overview of our references

Learn more

Electronic frost protection monitor

2-phase thermostat with continuous and switching output for reliable prevention of frost damages and freezing

THERMASREG® FS-20

Für jede Anwendung die richtige Lösung [Translate]

RPTF2 NTC30K

THERMASGARD® RPTF2 NTC30K

Item No. 1101-6071-7211-010
EAN 4 251325 605692

Resistance thermometer THERMASGARD® RPTF 2 with passive output that is specifically used for temperature detection in larger rooms or halls, for example, as a dark radiation sensor. The pendulum room sensor RPTF 2 (globe thermometer) determines the effective portion of active radiation or the effective radiant heat at the measured location. Due to the measuring method employed by this pendulum room temperature sensor in combination with its positioning in the room, an excellent measuring result that is representative of the room is achieved. The globe temperature is determined in order to take heat radiation into consideration and to estimate the degree of thermal comfort (operative room temperature). The operative room temperature describes the co-action of heat radiation and heat convection (the ratio of globe temperature/ air temperature is approx. 70% to 30%).

55,70 € net
Sensor NTC30kOhm
Connection type 2-wire connection
Testing current < 2.0 mW
Measuring range –5...+60 °C
Globe plastic, colour black, Ø = 50 mm
Insulating resistance ≥ 100 MΩ,
at +20 °C (500V DC)
Connection cable PVC; 1.5 m, H03VV-F, 2 x 0.25 mm²,
ends stripped with wire end sleeves
(other lengths optional: 3 m, 6 m)
Connection cable PVC, H03VV-F, 2 x 0.5 mm2,
ends stripped with wire end sleeves
KL = approx. 1.5 m (other lengths optional)
Humidity < 95 % r. H.
Protection class III (according to EN 60 730)
Protection type IP 65 (according to EN 60 529)

S+S Regeltechnik - Benefits to the power of five

Learn more

S+S Regeltechnik News

Exhibition Newsshow all

 

Light + Building 2020 – S+S Regeltechnik will be there
27.09. - 02.10.2020

Hall 9.1 | Booth A84
Be our guest at the world's leading trade fair for light, design and intelligent...
more

Overview of all exhibition dates

Product Newsshow all

 

HYGRASREG® TW ⁄ KW ⁄ KW-SD - Dew point and condensation control switches

These typical high-quality products from S+S feature innovative measuring, enclosure and connection...
more

 

THERMASGARD® TM65-Modbus -T3 - Calibratable immersion, screw-in or duct temperature measuring transducer

Patented high-quality product (patented immersion sensor, DE 10 2012 017 500.0) – basic device with...
more

Exhibition News

Light + Building 2020 | Frankfurt am Main | 27.09. - 02.10.2020

more

Newsletter Subscription

Stay always informed about our products and news from S+S Regeltechnik