Flexible sleeve/ cable temperature sensors TF65-F Pt1000 250mm
temperature Temperature

Flexible sleeve/ cable temperature sensors,
immersion/ screw-in temperature sensors THERMASGARD® TF65-F Pt1000 250mm

Item no. 1101-3060-5051-000
EAN 4251325617121
Product group: WG01

In Stock

Usually ships in 1 to 3 days
51,51 €
61,30 € incl. VAT + shipping
+

Description

Flexible sleeve/ cable temperature sensors,
immersion/ screw-in temperature sensors THERMASGARD® TF 65-F
Patented quality product (immersion sensor patent no. DE 10 2012 017 500.0)
The built-in/immersion temperature measuring transducer is an electric contact thermometres for temperature measurement in liquids and gases, and is designeed for installation in piping systems and vessels. For aggressive media, a stainless steel thermowell must be used.
Applications of this temperature sensor are found in piping systems, heating technology, storage tanks, district heating compact stations, hot and cold-water systems, oil and lubricant circulation systems, mechanical, equipment and plant engineering as well as in the entire industrial sector.

Technical details

Data points
température [°C]
Connection type
2-wire connection
Testing current
< 0.6 mA
Measuring range
–50...+180 °C
Ambient temperature
–20...+100 °C
Insulating resistance
100 MΩ,
at +20 °C (500V DC)
Electrical connection
0.14 - 1.5 mm²
via terminal screws on circuit board
Cable connection
cable gland, plastic (M 16 x 1.5; with strain relief, exchangeable, max. inner diameter 10.4 mm) or
M12 connector according to DIN EN 61076-2-101 (optional on request)
Housing
plastic, UV-stabilised,
material polyamide, 30 % glass-globe reinforced,
with quick-locking screws
(slotted/ Phillips head - combination),
colour traffic white (similar to RAL 9016)
Housing dimensions
72 x 64 x 37,8 mm (Tyr 1)
Cable gland
M 16 x 1.5, including strain relief, exchangeable,
max. inner diameter 10.4 mm
Cable length
250 mm
sensor cable
silicone, SiHF, 2 x 0.25 mm²,
CL = flexible, IL > 50 mm
Permissible air humidity
< 95 % RH, non-precipitating air
Protection class
III (according to EN 60 730)
Protection type
IP 67 (according to EN 60 529) only housing!
IP 65 (according to EN 60 529) humidity-tight stamped
IP 68 (optional sensor sleeve watertight compound-filled)
Protection type (sensor)
IP 65 (according to EN 60 529) sleeve humidity-tight (standard)
IP 68 (according to EN 60 529) sleeve water-tight (optional)

Accessories