PREMASREG 7111-U Q LCD

PREMASREG® PREMASREG 7111-U Q

Item No. 2004-6132-4100-001

The electronic PREMASREG® 711x pressure sensors and switches are equipped with eight switchable measuring ranges, one switching output, one continuous output, and a display for setting the switchpoint and to display the ACTUAL pressure (eight devices in one, plus differential pressure switch/ differential pressure monitor, continuous pressure sensor in a single device).

The pressure sensor with a housing made from impact-resistant plastic or stainless steel V4A, with cable fitting or bushing for M12 connector according to DIN EN 61076-2-101 and with metal pressure port nozzles (quick connect optional) is used to measure positive, negative or differential pressures in clean air, with limit value switching. The piezoresistive measuring element guarantees a high degree of reliability and accuracy.

Applications of these pressure sensors are in clean room, medical and filter technology, in ventilation and air conditioning ducts, in spray booths, in large-scale catering facilities, for filter monitoring and level measurement or for triggering frequency converters. Media measured with these pressure transducers are air (non-precipitating), or other gaseous, non-aggressive, non-combustible media.

The pressure sensor has a button for manual zero point calibration (automatic zero point calibration optional) and one offset potentiometer for setting the switching point and one for final value correction. The delivery includes the connection set ASD-06 (2 m connection hose, two pressure port nipples, screws).

238,34 € net
Voltage supply 24 V AC/ DC (± 20 %)
Power consumption < 1.1 VA/ 24 V DC ; < 2.2 VA/ 24 V AC
Load resistance RL > 5 kOhm
Output signal 0 -10 V
1 changeover contact (24 V), 1 A ohmic load
Connection type 3-wire connection
Measuring ranges 0... 100 Pa/ – 100... + 100 Pa
0... 300 Pa/ – 300... + 300 Pa
0... 500 Pa/ – 500... + 500 Pa
0... 1000 Pa/ – 1000... + 1000 Pa
Media temperature –20...+50 °C
Pressure connection equipped as standard with metal connection nozzles
for pressure hose Ø 4/ 6 mm,
optionally with quick connect made from stainless steel
for PVC fabric pressure hose Ø 6 mm
Type of pressure differential pressure
Accuracy (1000 Pa): typically ± 5 Pa
compared to the calibrated reference device
Zero point offset < ± 0.7 % of final value
Above- ⁄ below-pressure max. ± 100 hPa
Medium clean air and
non-aggressive, non-combustible gases
Signal filtering switchable 1 s/ 10 s
Setting increment Δp 1 % of pressure range (100 Pa => 1 Pa; 5000 Pa => 50 Pa)
Switching hysteresis ± 1 % of pressure range (100 Pa => ± 1 Pa; 5000 Pa => ± 50 Pa)
Electrical connection 0.14 - 1.5 mm², via plug-in screw terminal
Cable connection with M12 connector
according to DIN EN 61076-2-101
Housing plastic, UV-stabilised,
material polyamide, 30 % glass-globe reinforced,
with quick-locking screws
(slotted/ Phillips head - combination),
colour traffic white (similar to RAL 9016),
housing cover for display is transparent !
Housing dimensions 126 x 90 x 50 mm (Tyr 2)
Sum of Linearity+hysteresis < ± 1 % of final value
Temperature drift values ± 0.1 %/ °C
Air humidity < 95 % r. H., non-precipitating air
Protection class III (according to EN 60 730)
Protection type IP 65 (according to EN 60 529)
Standards CE conformity,
according to EMC directive 2014/ 30/ EU,
according to EN 61326-1, according to EN 61326-2-3
Features three-line display with illumination,
cutout approx. 70 x 40 mm (W x H),
for displaying ACTUAL pressure and/ or SETPOINT pressure
and for adjusting the automatic zero point calibration
Type Item No. Price
ASD-06 Connection set (nipple straight) Connection set (nipple straight) 7100-0060-3000-000 6,45 €
ASD-07 Connection nipple (at 90° angle) Connection nipple (at 90° angle) 7100-0060-7000-000 6,45 €

S+S Regeltechnik - Benefits to the power of five

Learn more

S+S Regeltechnik News

Exhibition Newsshow all

 

sps smart production solutions – S+S Regeltechnik will be there 26. - 28.11.2019

Be our guest at Europe's leading trade fair for electric automation from 26 to 28 November 2018. ...
more

Overview of all exhibition dates

Product Newsshow all

 

THERMASGARD® TM65-Modbus -T3 - Calibratable immersion, screw-in or duct temperature measuring transducer

Patented high-quality product (patented immersion sensor, DE 10 2012 017 500.0) – basic device with...
more

 

PREMASGARD® 211x, 212x and 212x-SD - Compact and flexible specialists in pressure

These calibratable compact sensors from S+S can manage up to eight switchable measuring ranges from...
more

Exhibition News

sps smart production solutions | 26. - 28.11.2019 | Nürnberg

more

Newsletter Subscription

Stay always informed about our products and news from S+S Regeltechnik