Construction progress of the Giga factory for sensor technology

The structural work on the production halls and offices at our new location in Nuremberg, Germany is nearing completion. Construction is progressing according to plan, so we are well positioned for the future and the increasing demand for our sensors.

Watch the video

Groundbreaking ceremony for significant growth

The office and manufacturing space alone at the new S+S location in Nuremberg will be expanded to 8,600 m² in order to meet the increasing demand for advanced sensor devices.

Watch the video

With Giga factory for sensors to become the #1 on the market

On a total area of over 14000 square meters, the new S+S company headquarters is being built in the north of Nuremberg.

Watch the video

Specialists in pressure

Multi-range measuring transducers for pressure, differential pressure and volume flow

PREMASGARD 211x / 212x

Efficient, convenient and network-enabled

Elegant appearance, touch-operated interface, large display, and Modbus-compatible

RYMaskon

Multi-funtional duct sensor

For humidity, temperature, pressure, differential pressure and volume flow for monitoring and controlling heating, ventilation and air-conditioning systems

PREMASGARD® 814x-Modbus

Satisfied customers drive our business

An overview of our references

Learn more

Electronic frost protection monitor

2-phase thermostat with continuous and switching output for reliable prevention of frost damages and freezing

THERMASREG® FS-20

Für jede Anwendung die richtige Lösung [Translate]

DS-205 B

PREMASREG® DS-205 B

Item No. 1302-4022-0000-000
EAN 4 251325 612805

The mechanical differential pressure switch/ differential pressure monitor PREMASREG® DS-2 with 4-hole plastic base ring, is used for monitoring above-atmospheric, differential and below-atmospheric pressure of clean air, gaseous, non-aggressive media in air ducts, air intake or exhaust devices. As a flow monitor, differential pressure governor, pressure controller for flow monitoring at electric heating registers as well as for monitoring V-belts and filters, as air pressure deficiency protection for monitoring ventilators, dampers, or as a limit value controller. Switchpoint adjustment is done internally using the internal precision scale. These instruments are factory-calibrated.

The DS-2 differential pressure sensor is supplied including the ASD-06 connection set (2 m connection hose, two pressure connection nipples, screws).

30,35 € net
Max. pressure 5000 Pa (50 mbar)
Pressure range high adjustment accuracy due to individual laser-etched scale
for each switch
Pressure range (adjustable) 50… 500 Pa (0.5...5.0 mbar)
Switching capacity (Contact load) 5 (0.8) A, 250 V AC
4 (0.7) A, 30 V DC
Contact single-pole potential-free changeover contact,
multi-layer contact, gold-plated (DDC compatible)
Media temperature –30 ...+85 °C
Operating Difference approx. 0.2 mbar ± 15 %
Pressure connection P1 (+) for higher pressure
P2 (–) for lower pressure
Ø 6.2 mm (nipples)
Electrical connection 0.14 - 1.5 mm2,
via terminal screws on circuit board
Housing base: material PC (10 % GF),
colour light grey (similar to RAL 7035),
snap-on lid: material PC, transparent,
cable gland PG 11 with strain relief
Membrane silicone, LSR (Liquid Silicon Rubber,
tempered at +200 °C, non-outgassing, LABS-free,
no emission of varnish-adhesion inhibiting substances),
long-term stability of switching points
due to trapezoidal bead membranes
Humidity < 90 % r. H., non-precipitating air
Mounting by 4-hole base ring, plastic
(included in the scope of delivery),
recommended mounting position:
vertical (pressure connections downward) – factory setting,
horizontal (cap up/ down)
Protection class II (according to EN 60 730)
Protection type IP 54 with top cover (according to EN 60529)
Standards CE conformity,
low-voltage directive 2014/ 35/ EU
Tests DVGW (according to DIN 1854),
VDE 0630, EN 61058,
directive on gas devices 2009/ 142/ EU,
CE 0085 A P 0918
Function Contact 1 - 2 breaks when pressure/ differential pressure
rises to the preset value.
Contact 1 - 3 closes when pressure/ differential pressure
drops and can be used as signal contact.
Type Item No. Price
ASD-06 Connection set (nipple straight) Connection set (nipple straight) 7100-0060-3000-000 6,61 €
ASD-07 Connection nipple (at 90° angle) Connection nipple (at 90° angle) 7100-0060-7000-000 6,61 €

S+S Regeltechnik - Benefits to the power of five

Learn more

S+S Regeltechnik News

Exhibition Newsshow all

 

Light + Building 2020 – S+S Regeltechnik will be there
27.09. - 02.10.2020

Hall 9.1 | Booth A84
Be our guest at the world's leading trade fair for light, design and intelligent...
more

Overview of all exhibition dates

Product Newsshow all

 

THERMASGARD® TM65-Modbus -T3 - Calibratable immersion, screw-in or duct temperature measuring transducer

Patented high-quality product (patented immersion sensor, DE 10 2012 017 500.0) – basic device with...
more

 

PREMASGARD® 211x, 212x and 212x-SD - Compact and flexible specialists in pressure

These calibratable compact sensors from S+S can manage up to eight switchable measuring ranges from...
more

Exhibition News

Light + Building 2020 | Frankfurt am Main | 27.09. - 02.10.2020

more

Newsletter Subscription

Stay always informed about our products and news from S+S Regeltechnik