Construction progress of the Giga factory for sensor technology

The structural work on the production halls and offices at our new location in Nuremberg, Germany is nearing completion. Construction is progressing according to plan, so we are well positioned for the future and the increasing demand for our sensors.

Watch the video

Groundbreaking ceremony for significant growth

The office and manufacturing space alone at the new S+S location in Nuremberg will be expanded to 8,600 m² in order to meet the increasing demand for advanced sensor devices.

Watch the video

With Giga factory for sensors to become the #1 on the market

On a total area of over 14000 square meters, the new S+S company headquarters is being built in the north of Nuremberg.

Watch the video

Specialists in pressure

Multi-range measuring transducers for pressure, differential pressure and volume flow

PREMASGARD 211x / 212x

Efficient, convenient and network-enabled

Elegant appearance, touch-operated interface, large display, and Modbus-compatible

RYMaskon

Multi-funtional duct sensor

For humidity, temperature, pressure, differential pressure and volume flow for monitoring and controlling heating, ventilation and air-conditioning systems

PREMASGARD® 814x-Modbus

Satisfied customers drive our business

An overview of our references

Learn more

Electronic frost protection monitor

2-phase thermostat with continuous and switching output for reliable prevention of frost damages and freezing

THERMASREG® FS-20

Für jede Anwendung die richtige Lösung [Translate]

PREMASGARD 7112-U

PREMASGARD 7112-U

Item No. 1301-7111-0370-200
EAN 4 251325 612584

The calibratable PREMASGARD® 711x pressure sensors (series) are equipped with eight switchable measuring ranges and equipped with optional display (eight devices in one) and are used to measure above-atmospheric, below-atmospheric, or differential pressures in air. The piezoresistive measuring element is temperature-compensated and guarantees a high degree of reliability and precision.

Applications of these pressure sensors are in clean room, medical and filter technology, in ventilation and air conditioning ducts, in spray booths, in large-scale catering facilities, for monitoring filters, for level measurement or for triggering frequency converters. Media measured with these pressure transducers are clean air (non-precipitating), or other gaseous non-aggressive, non-combustible media.

The pressure sensor has a button for manual zero point calibration (automatic zero point calibration optional / standard at 25 Pa) and one offset potentiometer for final value correction. The delivery includes the connection set ASD-06 (2 m connection hose, two pressure connection nipples, screws).

234,19 € net
Voltage supply 24 V AC (± 20 %) and
15…36 V DC
Power consumption < 2 VA/ 24 V DC, < 3.5 VA/ 24 V AC
Load resistance RL > 5 kOhm
Output signal 4...20 mA
Connection type 2- or 3-wire connection
Measuring ranges multi-range switching with 8 switchable measuring ranges
Media temperature –20...+50 °C
Pressure connection 4/ 6 x 11 mm (hoses Ø = 4/ 6 mm),
metal pressure connection nozzles
Type of pressure differential pressure
Accuracy (25 Pa): typically ± 1 Pa
compared to the calibrated reference device
Zero point offset < ± 0.7 % of final value
± 1.4 % of final value for pressure ranges < 250 Pa
Above- ⁄ below-pressure max. ± 100 hPa
Medium clean air and
non-aggressive, non-combustible gases
Signal filtering switchable 1 s/ 10 s
Electrical connection 2- or 3-wire connection
0.14 - 1.5 mm², via plug-in screw terminal
Cable connection cable gland, plastic (M 16 x 1.5; with strain relief,
exchangeable, max. inner diameter 10.4 mm) or
M12 connector (male, 5-pin, A-code)
according to DIN EN 61076-2-101 (optional on request)
Housing plastic, UV-stabilised,
material polyamide, 30 % glass-globe reinforced,
with quick-locking screws
(slotted/ Phillips head - combination),
colour traffic white (similar to RAL 9016)
Cable gland M 16 x 1.5; including strain relief
Dimensions 126 x 90 x 50 mm (Tyr 2)
Sum of Linearity+hysteresis < ± 1 % of final value
± 2 % of final value for pressure ranges < ± 250 Pa
Temperature drift values ± 0.1 % / °C
± 0.3 % / °C for pressure ranges < 250 Pa
Air humidity < 95 % r. H., non-precipitating air
Protection class III (according to EN 60 730)
Protection type IP 65 (according to EN 60 529)
Standards CE conformity,
according to EMC directive 2014/ 30/ EU,
according to EN 61326-1, according to EN 61326-2-3
Type Item No. Price
ASD-06 Connection set (nipple straight) Connection set (nipple straight) 7100-0060-3000-000 6,61 €
ASD-07 Connection nipple (at 90° angle) Connection nipple (at 90° angle) 7100-0060-7000-000 6,61 €
WS-03 Weather and sun protection Weather and sun protection 7100-0040-6000-000 38,68 €

S+S Regeltechnik - Benefits to the power of five

Learn more

S+S Regeltechnik News

Exhibition Newsshow all

 

Light + Building 2020 – S+S Regeltechnik will be there
27.09. - 02.10.2020

Hall 9.1 | Booth A84
Be our guest at the world's leading trade fair for light, design and intelligent...
more

Overview of all exhibition dates

Product Newsshow all

 

THERMASGARD® TM65-Modbus -T3 - Calibratable immersion, screw-in or duct temperature measuring transducer

Patented high-quality product (patented immersion sensor, DE 10 2012 017 500.0) – basic device with...
more

 

PREMASGARD® 211x, 212x and 212x-SD - Compact and flexible specialists in pressure

These calibratable compact sensors from S+S can manage up to eight switchable measuring ranges from...
more

Exhibition News

Light + Building 2020 | Frankfurt am Main | 27.09. - 02.10.2020

more

Newsletter Subscription