Pressure measuring transducer PREMASGARD SHD-I 16 LCD

Pressure measuring transducer PREMASGARD® SHD-I 16 LCD

Item no. 1301-2112-5570-121
EAN 4251325645612
Product group: WG01

Low availability.

Usually ships in 3 to 5 days
354,97 €
422,41 € incl. VAT + shipping
+

Description

Pressure measuring transducer PREMASGARD® SHD/SHD-SD LCD
The PREMASGARD® SHD pressure sensor is used to measure relative pressures (max. 0...40 bar) in gaseous and liquid media. The pressure measuring cell is welded to the pressure sensor without any seals.
The SHD-xx-LCD device variant is supplied with an LCD-SHD display module. It is mounted below the angle connector. The module can be mechanically rotated and tilted, and the display content can be rotated in 90° increments to achieve the ideal reading position. The display types and pressure unit are configured directly on the display (menu-driven via buttons).
The pressure transducer converts the measured variable into a standard signal of 0 - 10 V or 4...20 mA. The process connection is G ½ . This pressure transmitter is used in hydraulics, pneumatics, process technology, mechanical and plant engineering.

Technical details

Voltage supply
24 V AC/ DC for output 0 -10 V
7 - 33 V DC for output 4 ... 20 mA
Response time
2 ms (1 ms typical)
Characteristic line
± 0,3 %
Output
4...20 mA
Output signal
4... 20 mA, 2-wire, (working resistance < (UB (V) -7 V)/ 0,02 A ;
RL depending on working resistance
Measuring range
0...16 bar
Measuring principle
steel measuring cell (suitable for ammonia and freons)
Media temperature
– 40...+135 °C
Pressure connection
G ½ " sealing at the back, and manometer (combined)
with profile gasket FPM, special WW G ¼ " DIN 3852
Type of pressure
relative
Overload range
< 6 bar: 5 x of final value
> 6 bar: 3 x of final value (max. 1500 bar)
Bursting pressure
< 6 bar: 10 x of final value
> 6 bar: 6 x of final value (max. 2500 bar)
Permissible medium
suitable for ammonia and freons
Electrical connection
0.25 - 1.5 mm², via plug-in connector DIN EN 175301-803-A
Housing
stainless steel 1.4305
Connecting head
plastic, approx. 98 x 50 x 34 mm
Installation
directly on pressure line
Medium contacting parts
Stainless steel V2A (1.4305)
Protection class
III (according to EN 60 730)
Protection type
IP 65 (according to EN 60 529)*
Standards
CE conformity, electromagnetic compatibility
in accordance with EMC Directive 2014/ 30/ EU, EN 61 326
Display
LCD display (16x27.5 mm)
multi-line; three-digit; display can be rotated and tilted

Accessories