Specialists in pressure

Multi-range measuring transducers for pressure, differential pressure and volume flow

PREMASGARD 211x / 212x

Efficient, convenient and network-enabled

Elegant appearance, touch-operated interface, large display, and Modbus-compatible

RYMaskon

Multi-funtional duct sensor

For humidity, temperature, pressure, differential pressure and volume flow for monitoring and controlling heating, ventilation and air-conditioning systems

PREMASGARD® 814x-Modbus

Satisfied customers drive our business

An overview of our references

Learn more

Electronic frost protection monitor

2-phase thermostat with continuous and switching output for reliable prevention of frost damages and freezing

THERMASREG® FS-20

Für jede Anwendung die richtige Lösung [Translate]

KFTM-LQ-CO2 MODBUS LCD

AERASGARD® KFTM-LQ-CO2 MODBUS

Item No. 1501-8118-6071-200
EAN 4 251325 613680

Patentiertes Qualitätsprodukt (Patent-Nr. DE 10 2014 010 719.1)

Der wartungsfreie mikroprozessorgesteuerte AERASGARD® KFTM - LQ - CO2 - Modbus bzw. KCO2 - Modbus/ KLQ - CO2 - Modbus mit Modbus-Anschluss, wahlweise mit/ ohne Display, ist zur Kanalmontage und dient zur Erfassung aller für ein Raumklima relevanten Messgrößen. Hierzu werden die Messgrößen Luftfeuchtigkeit, Temperatur, CO2 Konzentration sowie Luftqualität (VOC) gemessen. Durch Erfassung aller vier Messgrößen in einem Gerät kann das gesamte Raumklima effektiv überwacht und gesteuert werden. Er misst CO2 im Bereich von 0...5000 ppm, VOC in einer von drei wählbaren Sensibilitätsstufen LOW / MEDIUM / HIGH, Temperaturen im Bereich von –35...+80 °C sowie die relative Luftfeuchtigkeit von 0...100 % r.H.

Die relative Feuchte (% r.H.) ist der Quotient aus dem Wasserdampfpartialdruck und dem Sättigungsdampfdruck bei der jeweiligen Gastemperatur. Ein digitaler, langzeitstabiler Sensor als Messelement für relative Luftfeuchte und Temperatur garantiert exakte Messergebnisse.

Der CO2Gehalt der Luft wird mittels optischen NDIR-Sensors (nicht-dispersive Infrarot-Technologie) ermittelt. Der Erfassungsbereich der Sensoren wird auf Standardanwendungen wie z. B. Wohn und Tagungsraum überwachung kalibriert. Bedarfsgerechte Lüftung, Steigerung des Wohlbefindens und des Kundennutzens, erhöhter Komfort sowie eine Senkung der Betriebskosten durch Energieeinsparung sind nur einige Ergebnisse des Einsatzes des AERASGARD® CO2.

Obige Ausführungen zeigen, dass es Anwendungen für CO2-Messungen, Anwendungen für VOC-Messungen aber aus unserer Sicht vorrangig Anwendungen für die Kombination bei der Messgrößen gibt. Wichtig hierbei ist, dass sich diese beiden Messgrößen nicht ineinander umrechnen bzw. Ableitungen zueinander herstellen lassen. Ein NDIR-CO2 Messgerät misst selektiv kann keine VOCs detektieren, ein VOC-Mischgassensor kann keine CO2 Moleküle erfassen.

508,98 € net
Voltage supply 24 V AC/ DC (± 10 %)
Power consumption < 4.4 W/ 24 V DC typical; < 6.4 VA/ 24 V AC typical;
peak current 200 mA
Data points temperature, relative humidity,
air quality (VOC), carbon dioxide (CO2),
atmospheric pressure
Sensors digital humidity sensor
with integrated temperature sensor,

low hysteresis, high long-term stability
Measuring range, humidity 0...100 % r. H.
Operating range, humidity 0...95 % r. H. (without dew formation)
Deviation of humidity typical ± 2 % r. H. (20…80 % r. H. ); at + 25 °C, otherwise ± 3 %
Measuring range, temperature –35...+80 °C
Operating range, temperature –10...+60 °C
Temperature deviation typically ± 0.2 K at +25 °C
Sensor, VOC VOC sensor (metal oxide) with automatic calibration
(VOC = volatile organic compounds)
Measuring range, VOC 0...100 % air quality; referred to calibrating gas;
multi-range switching (selectable via DIP switches)
VOC sensitivity low, medium, high
Measuring accuracy, VOC ± 20 % of final value (referred to calibrating gas)
Service life > 60 months (under normal load conditions)
Measuring range, CO2 0...5000 ppm
Sensor, CO2 optical NDIR sensor (non-dispersive infra-red technology)
including atmospheric pressure compensation (up to 1100 mbar)
with automatic and manual calibration
Measuring accuracy, CO2 typically ± 30 ppm ± 3 % of measured value
Temperature dependence, CO2 ± 5 ppm/ °C or ± 0.5 % of measured value/ °C
(whichever is higher)
Pressure dependence ± 0,13 %/ mm Hg
Gas exchange by diffusion
Response time < 2 minutes
Sensor protection plastic sinter filter, Ø 16 mm, L = 35 mm, exchangeable
(optional metal sinter filter, Ø 16 mm, L = 32 mm)
Ambient temperature –10...+60 °C
Bus protocol Modbus (RTU mode),
address range 0...247 selectable
Signal filtering 4 s / 32 s
Process connection by mounting flange, plastic
(included in the scope of delivery)
Protective tube PLEUROFORMTM, material polyamide (PA6), with torsion protection, Ø 20 mm, vmax = 30 m/s (air)
without filter: NL = 202.5 mm / with plastic filter: NL = 235 mm (optional with metal filter: NL = 227 mm)
Electrical connection 0.14 - 1.5 mm2, via push-in terminal
Housing plastic, UV-stabilised,
material polyamide, 30 % glass-globe reinforced,
with quick-locking screws
(slotted/ Phillips head - combination),
colour traffic white (similar to RAL 9016),
housing cover for display is transparent !
Housing dimensions 126 x 90 x 50 mm (Tyr 2)
Cable gland 2x M 16 x 1.5; including strain relief, exchangeable
Long-term stability < 2 % in 15 years
Protection class III (according to EN 60 730)
Protection type IP 65 (according to EN 60 529) housing only! (PLEUROFORM IP 30)
Standards

CE-Konformitat, elektromagnetische
Vertraglichkeit nach EN 61326,
nach EMV-Richtlinie 2014/ 30/ EU

Display three-line display with illumination, cutout approx. 70 x 40 mm (W x H),
for displaying actual humidity, actual temperature, air quality and / or the actual CO2 content
Type Item No. Price
KA-2 1906-1200-0000-100 0,00 €

S+S Regeltechnik - Benefits to the power of five

Learn more

S+S Regeltechnik News

Exhibition Newsshow all

 

sps smart production solutions – S+S Regeltechnik will be there 26. - 28.11.2019

Booth 8-219
Be our guest at Europe's leading trade fair for electric automation from 26 to...
more

Overview of all exhibition dates

Product Newsshow all

 

THERMASGARD® TM65-Modbus -T3 - Calibratable immersion, screw-in or duct temperature measuring transducer

Patented high-quality product (patented immersion sensor, DE 10 2012 017 500.0) – basic device with...
more

 

PREMASGARD® 211x, 212x and 212x-SD - Compact and flexible specialists in pressure

These calibratable compact sensors from S+S can manage up to eight switchable measuring ranges from...
more

Exhibition News

sps smart production solutions | 26. - 28.11.2019 | Nürnberg

more

Newsletter Subscription

Stay always informed about our products and news from S+S Regeltechnik