Efficient, convenient and network-enabled
Elegant appearance, touch-operated interface, large display, and Modbus-compatible
RYMaskon
The maintenance-free, microprocessor-controlled AERASGARD® AFTM - LQ - CO2 - Modbus and ACO2 - Modbus ⁄ ALQ - CO2 - Modbus with Modbus connection, with ⁄ without optional display, is designed for on-wall installation and is used to monitor all measurands of relevance to the climate inside a room. These are the measurands air humidity, temperature, CO2 concentration as well as air quality (VOC). By using a single device to monitor all four measurands, it is possible to effectively monitor and regulate the entire room climate. It measures CO2 in the range of 0...5000 ppm, VOC at one of three selectable sensitivity levels LOW / MEDIUM / HIGH, temperatures in the range of –35...+80 °C, as well as relative air humidity from 0...100 % r.H.
The relative humidity (% r.H.) quotient of water vapour partial pressure divided by the saturation vapour pressure at the respective gas temperature. A digital, long-term stable sensor used as measuring element for relative air humidity and temperature guarantees exact measurement results.
The CO2 content of the air is measured using an optical NDIR sensor (non-dispersive infra-red technology). The detection range of the sensors is calibrated for standard applications such as monitoring residential rooms and conference rooms. Room ventilation on an as-needed basis, improved well-being and customer benefit, increased comfort as well as reduced operating costs through energy conservation are just some of the benefits of employing the AERASGARD® CO2 sensor.
The explanations above demonstrate that there are applications for CO2 measurements, for VOC measure ments, but from our perspective, above all, for a combination of both measurands. The crucial factor in this respect is that both of these measurands are not convertible into each other and derivations to or from one another cannot be made. An NDIR CO2 measuring instrument measures selectively and cannot detect any VOC; a VOC mixed gas sensor cannot recognize CO2 molecules.
Voltage supply | 24 V AC ⁄ DC (± 10 %) |
---|---|
Power consumption |
< 4.4 W ⁄ 24 V DC typical; < 6.4 VA ⁄ 24 V AC typical; peak current 200 mA |
Data points |
temperature, relative humidity, air quality (VOC), carbon dioxide (CO2), atmospheric pressure |
Sensors |
digital humidity sensor
with integrated temperature sensor, low hysteresis, high long-term stability |
Measuring range, humidity | 0...100 % r. H. |
Operating range, humidity | 0...95 % r. H. (without dew formation) |
Deviation of humidity | typical ± 2 % r. H. (20…80 % r. H. ); at + 25 °C, otherwise ± 3 % |
Measuring range, temperature | –35...+80 °C |
Operating range, temperature | –10...+60 °C |
Temperature deviation | typically ± 0.2 K at +25 °C |
Measuring range, CO2 | 0...5000 ppm |
Sensor, CO2 |
optical NDIR sensor (non-dispersive infra-red technology) with automatic and manual calibration |
Measuring accuracy, CO2 | typically ± 30 ppm ± 3 % of measured value |
Temperature dependence, CO2 |
± 5 ppm ⁄ °C or ± 0.5 % of measured value ⁄ °C (whichever is higher) |
Pressure dependence | ± 0,13 % ⁄ mm Hg |
Gas exchange | by diffusion |
Response time | < 2 minutes |
Sensor protection |
plastic sinter filter, Ø 16 mm, L = 35 mm, exchangeable (optional metal sinter filter, Ø 16 mm, L = 32 mm) |
Ambient temperature | –10...+60 °C |
Bus protocol |
Modbus (RTU mode), address range 0...247 selectable |
Signal filtering | 4 s / 32 s |
Process connection | by screws |
Protective tube | stainless steel V2A (1.4301), Ø 16 mm, NL = 55 mm |
Electrical connection | 0.14 - 1.5 mm2, via push-in terminal |
Enclosure |
plastic, UV-stabilised, material polyamide, 30 % glass-globe reinforced, with quick-locking screws (slotted ⁄ Phillips head - combination), colour traffic white (similar to RAL 9016) |
Enclosure dimensions | 126 x 90 x 50 mm (Tyr 2) |
Cable gland | 2x M 16 x 1.5; including strain relief, exchangeable |
Long-term stability | < 2 % in 15 years |
Protection class | III (according to EN 60 730) |
Protection type | IP 65 (according to EN 60 529) |
Standards |
CE conformity, electromagnetic compatibility according to EN 61326, according to EMC Directive 2014 ⁄ 30 ⁄ EU |
ISH Messe Frankfurt – S+S Regeltechnik looks forward to meeting you!
11. - 15.03.2019
Stand 10.3 A71
At the ISH, the world's leading trade fair for "The Bathroom Experience,...
more
Multi-functional duct sensor for monitoring and control of heating, ventilation and air-conditioning systems
This bus capable and calibratable pressure measuring transducer enables the control of differential...
more
Good room climate is measurable! - AERASGARD® FSCO2 ⁄ FSTM-CO2 ⁄ FSFTM-CO2-Modbus
Our multifunctional room sensors for measuring temperature, humidity and CO2 concentration can now...
more
ISH | 11. - 15.03.2019 | Stand 10.3 A71
more