Groundbreaking ceremony for significant growth

The office and manufacturing space alone at the new S+S location in Nuremberg will be expanded to 8,600 m² in order to meet the increasing demand for advanced sensor devices.

Watch the video

With Giga factory for sensors to become the #1 on the market

On a total area of over 14000 square meters, the new S+S company headquarters is being built in the north of Nuremberg.

Watch the video

Specialists in pressure

Multi-range measuring transducers for pressure, differential pressure and volume flow

PREMASGARD 211x / 212x

Efficient, convenient and network-enabled

Elegant appearance, touch-operated interface, large display, and Modbus-compatible

RYMaskon

Multi-funtional duct sensor

For humidity, temperature, pressure, differential pressure and volume flow for monitoring and controlling heating, ventilation and air-conditioning systems

PREMASGARD® 814x-Modbus

Satisfied customers drive our business

An overview of our references

Learn more

Electronic frost protection monitor

2-phase thermostat with continuous and switching output for reliable prevention of frost damages and freezing

THERMASREG® FS-20

Für jede Anwendung die richtige Lösung [Translate]

RPTM2-MODBUS LCD

THERMASGARD® RPTM2-MODBUS

Item No. 1101-1276-2210-000
EAN 4 251325 600895

calibratable resistance thermometer with globe THERMASGARD® RPTM 2 - Modbus with Modbus connection, terminal box housing made of impact-resistant plastic, housing cover with quick-locking screws, with/ without optional display indicating the actual temperature.

The pendulum room sensor is specifically designed for temperature detection in larger rooms or halls, for example, as a dark radiation sensor. Due to the measuring method employed by this pendulum room temperature sensor in combination with its positioning in the room, an excellent measuring result that is representative of the room is achieved. The globe thermometer determines the effective portion of active radiation or the effective radiant heat at the measured location. The globe temperature is determined in order to take heat radiation into consideration and to estimate the degree of thermal comfort (operative room temperature). The operative room temperature describes the co-action of heat radiation and heat convection (the ratio of globe temperature/ air temperature is approx. 70 % to 30 %). The sensors are factory-calibrated. Adjustment/ fine adjustment by the user is possible (zero point offset is adjustable).

192,30 € net
Voltage supply 24 V AC (± 20 %) and
15…36 V DC
Power consumption < 1,0 VA/ 24 V DC
< 2,2 VA/ 24 V AC
Temperature deviation typically ± 0.2 K at +25 °C
Sensor Pt1000, DIN EN 60751, class B
Measuring range – 50...+ 150 °C; Tmin –50 °C, Tmax + 80 °C
Zero point offset ± 10 °C
Ambient temperature Measuring transducer –30...+70 °C
Medium clean air and
non-aggressive, non-combustible gases
Error detection sensor breakage, sensor short circuit
Bus protocol Modbus (RTU mode),
address range 0...247 selectable
Signal filtering 0,3 s / 1 s / 10 s
Globe plastic, colour black, Ø = 50 mm
Connection cable PVC; LiYY, 1.5 m
(other lengths optional: e.g. 3 m, 6 m)
Housing plastic, UV-stabilised,
material polyamide, 30 % glass-globe reinforced,
with quick-locking screws
(slotted/ Phillips head - combination),
colour traffic white (similar to RAL 9016),
housing cover for display is transparent !
Housing dimensions 72 x 64 x 43.3 mm (Tyr 1 with Display)
Cable gland 2x M 12 x 1.5 (Y-adapter); with strain relief,
exchangeable, max. inner diameter 6 mm
Connection cable PVC, H03VV-F, 2 x 0.5 mm2,
KL = approx. 1.5 m (other lengths optional)
Permissible air humidity < 95 % r. H., non-precipitating air
Protection class III (according to EN 60 730)
Protection type IP 65 (according to EN 60 529)
Standards CE conformity,
electromagnetic compatibility according to EN 61326,
according to EMC Directive 2014/ 30/ EU
Display two-line display with illumination, programmable,
cutout approx. 36 x 15 mm (W x H),
for displaying the actual temperature or
an individually programmable display value
(The Modbus interface allows the display to be individually
configured in the 7-segment area and in the dot-matrix area.)
Type Item No. Price
KA2-MODBUS 1906-1200-0000-100 185,00 €
MODBUS-Y Y-adapter Y-adapter as bypass for bus connection 7000-0005-0002-100 9,10 €

S+S Regeltechnik - Benefits to the power of five

Learn more

S+S Regeltechnik News

Exhibition Newsshow all

Swiss Bau 2020 – S+S Regeltechnik will be there
14.01. - 18.01.2020

Hall 1.2 / Booth B22
Be our guest at the largest construction fair in Switzerland from January 14 to...
more

Overview of all exhibition dates

Product Newsshow all

 

THERMASGARD® TM65-Modbus -T3 - Calibratable immersion, screw-in or duct temperature measuring transducer

Patented high-quality product (patented immersion sensor, DE 10 2012 017 500.0) – basic device with...
more

 

PREMASGARD® 211x, 212x and 212x-SD - Compact and flexible specialists in pressure

These calibratable compact sensors from S+S can manage up to eight switchable measuring ranges from...
more

Exhibition News

SWISS BAU | Basel | 14. – 18. 01. 2020 | (Hall 1.2 / Booth B22)

more

Newsletter Subscription

Stay always informed about our products and news from S+S Regeltechnik