Construction progress of the Giga factory for sensor technology

The structural work on the production halls and offices at our new location in Nuremberg, Germany is nearing completion. Construction is progressing according to plan, so we are well positioned for the future and the increasing demand for our sensors.

Watch the video

Groundbreaking ceremony for significant growth

The office and manufacturing space alone at the new S+S location in Nuremberg will be expanded to 8,600 m² in order to meet the increasing demand for advanced sensor devices.

Watch the video

With Giga factory for sensors to become the #1 on the market

On a total area of over 14000 square meters, the new S+S company headquarters is being built in the north of Nuremberg.

Watch the video

Specialists in pressure

Multi-range measuring transducers for pressure, differential pressure and volume flow

PREMASGARD 211x / 212x

Efficient, convenient and network-enabled

Elegant appearance, touch-operated interface, large display, and Modbus-compatible

RYMaskon

Multi-funtional duct sensor

For humidity, temperature, pressure, differential pressure and volume flow for monitoring and controlling heating, ventilation and air-conditioning systems

PREMASGARD® 814x-Modbus

Satisfied customers drive our business

An overview of our references

Learn more

Electronic frost protection monitor

2-phase thermostat with continuous and switching output for reliable prevention of frost damages and freezing

THERMASREG® FS-20

Für jede Anwendung die richtige Lösung [Translate]

AH-40W LCD

HYGRASREG® AH-40W LCD

Item No. 1202-1065-0221-000
EAN 4 251325 615523

Electronic hygrostat and humidity sensor HYGRASREG® AH - 40 with one switching output, adjustable switching threshold and display for indicating actual humidity (accuracy class ± 2.0 % r.H.) and for setting the target humidity.

They are used to control and monitor the relative humidity, e.g. in laboratories, production facilities, climatic test cabinets, indoor swimming pools, greenhouses, etc. to control humidifying and dehumidifying equipment. These measuring transducers are designed for exact detection of humidity. The AH - 40 uses a digital, long-term stable sensor as a measuring element for measuring humidity. It is used in dust-free, unpolluted, non-aggressive air.

156,83 € net
Voltage supply 24 V AC (± 20 %) and
15…36 V DC
Power consumption < 1.1 VA/ 24 V DC ; < 2.2 VA/ 24 V AC
Sensors digital humidity sensor
small hysteresis, high long-term stability
Deviation of humidity typical ± 2 % r. H. (20…80 % r. H. ); at + 25 °C, otherwise ± 3 %
Output potential-free changeover contact (24 V), 1 A ohmic load
Sensor protection plastic sinter filter, Ø 16 mm, L = 35 mm, exchangeable
(optional metal sinter filter, Ø 16 mm, L = 32 mm)
Setting range 5...95 % r. H.
Ambient temperature storage –35...+85 °C;
operation – 30...+75 °C, non-precipitating
Process connection by screws
Protective tube stainless steel V2A (1.4301), Ø 16 mm, NL = 55 mm
Electrical connection 0.14 - 1.5 mm² via terminal screws
Cable connection cable gland, plastic (M 16 x 1.5; with strain relief, exchangeable, max. inner diameter 10.4 mm) or
M12 connector according to DIN EN 61076-2-101 (optional on request)
Housing plastic, UV-stabilised,
material polyamide, 30 % glass-globe reinforced,
with quick-locking screws
(slotted/ Phillips head - combination),
colour traffic white (similar to RAL 9016),
housing cover for display is transparent !
Housing dimensions 72 x 64 x 43.3 mm (Tyr 1 with Display)
Cable gland M 16 x 1.5, including strain relief, exchangeable,
max. inner diameter 10.4 mm
Long-term stability ± 1 %/ year
Protection class III (according to EN 60 730)
Protection type IP 65 (according to EN 60 529) housing only!
Standards CE conformity,
electromagnetic compatibility according to EN 61326,
according to EMC Directive 2014/ 30/ EU
Display two-line display with illumination, cutout approx. 36 x15 mm (W x H),
for displaying actual humidit and for setting the target humidity
Displaying The 1st line of the display shows the relative humidity.
The 2nd line shows on the left side the information
regarding the switching status of the relay (as a circuit),
as well as the switching value readout in % r.H.
on the right side (adjustable using the set potentiometer).
Circuit, empty = relay in idle state
Circuit, full = relay energised
Function

The relay output is triggered (contact 13 -11 closed) if the humidity
switchpoint is not reached and opens (contact 12 -11 closed)
in the event of a fault (power failure, condensation)

LED short pulses =
relay active → switchpoint not reached

LED long pulses =
relay inactive → switchpoint exceeded

S+S Regeltechnik - Benefits to the power of five

Learn more

S+S Regeltechnik News

Exhibition Newsshow all

 

Light + Building 2020 – S+S Regeltechnik will be there
27.09. - 02.10.2020

Hall 9.1 | Booth A84
Be our guest at the world's leading trade fair for light, design and intelligent...
more

Overview of all exhibition dates

Product Newsshow all

 

THERMASGARD® TM65-Modbus -T3 - Calibratable immersion, screw-in or duct temperature measuring transducer

Patented high-quality product (patented immersion sensor, DE 10 2012 017 500.0) – basic device with...
more

 

PREMASGARD® 211x, 212x and 212x-SD - Compact and flexible specialists in pressure

These calibratable compact sensors from S+S can manage up to eight switchable measuring ranges from...
more

Exhibition News

Light + Building 2020 | Frankfurt am Main | 27.09. - 02.10.2020

more

Newsletter Subscription

Stay always informed about our products and news from S+S Regeltechnik