LS-2

HYGRASREG® LS-2

Item No. 1202-1042-0000-000
EAN 4 251325 611549

The leakage sensor ⁄ water ingress detector HYGRASREG® LS with leakage location is used to detect water ingress and ingress of conductive liquids. It is designed for the early detection of water leakages to protect sensitive electrical and electronic equipment in buildings against humidity. The water ingress detector consists of an electronic monitoring system and a matching electrode, which can be extended by the user.

87,90 € net
Voltage supply 24 V AC (± 20 %) and
15…36 V DC
Monitoring range conductive liquids between the probes
Switching threshold conductance between electrodes > threshold
Power consumption < 1,0 VA ⁄ 24 V DC
< 2,2 VA ⁄ 24 V AC
Output signal potential-free changeover contact (24 V), 1 A ohmic load
Process connection two external probes, laid according to measuring task (on the LS - 2)
or upright on four electrodes with insulating plastic caps
, which are mounted on the enclosure underside (on the LS - 4)
Electrical connection 0.14 - 1.5 mm² via terminal screws
Enclosure plastic, UV-stabilised,
material polyamide, 30 % glass-globe reinforced,
with quick-locking screws
(slotted ⁄ Phillips head - combination),
colour traffic white (similar to RAL 9016),
enclosure cover for display is transparent !
Enclosure dimensions 72 x 64 x 43.3 mm (Tyr 1 with Display)
Cable gland 2x M 12 x 1.5 (Y-adapter); with strain relief,
exchangeable, max. inner diameter 6 mm
Protection class III (according to EN 60 730)
Protection type IP 65 (according to EN 60 529)
Standards CE conformity,
electromagnetic compatibility according to EN 61326,
according to EMC Directive 2014 ⁄ 30 ⁄ EU
Function The leak sensor can be set using DIP switches so that
the relay is energised during normal operation.
This means that relay opens in the event of a fault
(water damage, cable breakage, power failure).
This also enables a break in the cable to the sensor to be detected.

S+S Regeltechnik - Benefits to the power of five

Learn more

S+S Regeltechnik News

Exhibition Newsshow all

 

ISH Messe Frankfurt – S+S Regeltechnik looks forward to meeting you!
10. - 15.03.2019

Stand 10.3 A71
At the ISH, the world's leading trade fair for "The Bathroom Experience,...
more

Overview of all exhibition dates

Product Newsshow all

 

Multi-functional duct sensor for monitoring and control of heating, ventilation and air-conditioning systems

This bus capable and calibratable pressure measuring transducer enables the control of differential...
more

 

Good room climate is measurable! - AERASGARD® FSCO2 ⁄ FSTM-CO2 ⁄ FSFTM-CO2-Modbus

Our multifunctional room sensors for measuring temperature, humidity and CO2 concentration can now...
more

Exhibition News

ISH | 10. - 15.03.2019 | Stand 10.3 A71

more

Newsletter Subscription

Stay always informed about our products and news from S+S Regeltechnik