Construction progress of the Giga factory for sensor technology

The structural work on the production halls and offices at our new location in Nuremberg, Germany is nearing completion. Construction is progressing according to plan, so we are well positioned for the future and the increasing demand for our sensors.

Watch the video

Groundbreaking ceremony for significant growth

The office and manufacturing space alone at the new S+S location in Nuremberg will be expanded to 8,600 m² in order to meet the increasing demand for advanced sensor devices.

Watch the video

With Giga factory for sensors to become the #1 on the market

On a total area of over 14000 square meters, the new S+S company headquarters is being built in the north of Nuremberg.

Watch the video

Specialists in pressure

Multi-range measuring transducers for pressure, differential pressure and volume flow

PREMASGARD 211x / 212x

Efficient, convenient and network-enabled

Elegant appearance, touch-operated interface, large display, and Modbus-compatible

RYMaskon

Multi-funtional duct sensor

For humidity, temperature, pressure, differential pressure and volume flow for monitoring and controlling heating, ventilation and air-conditioning systems

PREMASGARD® 814x-Modbus

Satisfied customers drive our business

An overview of our references

Learn more

Electronic frost protection monitor

2-phase thermostat with continuous and switching output for reliable prevention of frost damages and freezing

THERMASREG® FS-20

Für jede Anwendung die richtige Lösung [Translate]

TW-U/W

HYGRASREG® TW-U/W

Item No. 1202-1012-1001-020
EAN 4 251325 611556

The dew point control switch HYGRASREG® TW is installed on cooling or cold-water piping, or on cooled surfaces. It reliably detects formation of condensation by means of its humidity and temperature sensor (no conductivity measurement) and thanks to its patented measuring method, the pro-dynamic cross convention (Patent No. DE 10 2012 015 726.6), an exact measurement result, with/ without optional display.

Dew point temperature is that temperature at which air reaches the state of saturation and water vapour starts to condensate. Facilitated by the measuring range of 0...100 % relative humidity of the TW-U and by the adjustable threshold value of 75...100 % relative humidity of the TW-W, it is possible for example to operate cooling ceilings so that the switching output of the dew point monitor, the DDC, is activated and then triggers a heater or other control elements thereby preventing the formation of dew before dew builds up on pipes or cooling ceilings of the property to be monitored.

130,69 € net
Power consumption < 1.1 VA/ 24 V DC ; < 2.2 VA/ 24 V AC
Sensors digital humidity sensor
with integrated temperature sensor,

low hysteresis, high long-term stability
Output 0 -10 V
1 changeover contact (24 V), 1 A ohmic load
Output signal 0 -10 V
1 changeover contact (24 V), 1 A ohmic load
Sensor protection membrane filter
Measuring range formation of dew is detected at
0...100 % r.H. on the TW-U, continuous
Medium clean air and
non-aggressive, non-combustible gases
Process connection endless metal strap with metal tightener,
300 mm, for pipes up to 3 ''
(included in scope of delivery)
Electrical connection 0.14 - 1.5 mm² via terminal screws
Cable connection cable gland, plastic (M 16 x 1.5; with strain relief, exchangeable, max. inner diameter 10.4 mm) or
M12 connector according to DIN EN 61076-2-101 (optional on request)
Housing plastic, UV-stabilised,
material polyamide, 30 % glass-globe reinforced,
with quick-locking screws
(slotted/ Phillips head - combination),
colour traffic white (similar to RAL 9016)
Housing dimensions 72 x 64 x 37,8 mm (Tyr 1)
Cable gland M 16 x 1.5, including strain relief, exchangeable,
max. inner diameter 10.4 mm
Installation TW with strap for direct mounting on pipes
or for direct mounting on flat surfaces
(e.g. walls, ceilings)

TW - external with detached sensor head
(cable length KL = 1.5 m) for mounting on pipes

Protection class III (according to EN 60 730)
Protection type IP 65 (according to EN 60 529)
Standards CE conformity,
electromagnetic compatibility according to EN 61326,
according to EMC Directive 2014/ 30/ EU
Function The relay output is triggered (contact 13 -11 closed)
if the pre-set switchpoint (factory setting 75 % r.H.)
is not reached and opens (contact 12 -11 closed)
in the event of an error (power failure, condensation).

LED short pulses =
relay active → switchpoint not reached
ACTUAL humidity < pre-set switchpoint (no condensation)

LED long pulses =
relay inactive → switchpoint exceeded
ACTUAL humidity > pre-set switchpoint (condensation)

S+S Regeltechnik - Benefits to the power of five

Learn more

S+S Regeltechnik News

Exhibition Newsshow all

 

Light + Building 2020 – S+S Regeltechnik will be there
27.09. - 02.10.2020

Hall 9.1 | Booth A84
Be our guest at the world's leading trade fair for light, design and intelligent...
more

Overview of all exhibition dates

Product Newsshow all

 

THERMASGARD® TM65-Modbus -T3 - Calibratable immersion, screw-in or duct temperature measuring transducer

Patented high-quality product (patented immersion sensor, DE 10 2012 017 500.0) – basic device with...
more

 

PREMASGARD® 211x, 212x and 212x-SD - Compact and flexible specialists in pressure

These calibratable compact sensors from S+S can manage up to eight switchable measuring ranges from...
more

Exhibition News

Light + Building 2020 | Frankfurt am Main | 27.09. - 02.10.2020

more

Newsletter Subscription

Stay always informed about our products and news from S+S Regeltechnik