Description
Dew point control switches
HYGRASGARD® TW - Modbus - T3
Patented quality product
(pro-dynamic cross convection patent no. DE 10 2012 015 726.6)
W-Modbus is a wireless-based further development of the proven Modbus standard for the wireless connection of Modbus-enabled sensors, controllers and devices. W-Modbus devices communicate via a wireless radio link from LumenRadio - independently of the in-house Wi-Fi and without leaving the proven protocol standards. Thanks to the reliable and interference-resistant wireless network, entire buildings can be networked and the majority of Modbus RTU cables can be replaced.
(pro-dynamic cross convection patent no. DE 10 2012 015 726.6)
W-Modbus is a wireless-based further development of the proven Modbus standard for the wireless connection of Modbus-enabled sensors, controllers and devices. W-Modbus devices communicate via a wireless radio link from LumenRadio - independently of the in-house Wi-Fi and without leaving the proven protocol standards. Thanks to the reliable and interference-resistant wireless network, entire buildings can be networked and the majority of Modbus RTU cables can be replaced.
Innovative Modbus sensor with galvanically separated RS485-Modbus-interface, selectable
bus termination resistance, DIP switch for setting the bus parameters and bus address in
curent-free state, internal LEDs for telegram status display, two separate push-in terminals
and large three-line display (illuminated; with customised programming in the 7-segment and
dot-matrix range). The sensor is factory-calibrated; an environmental precision adjustment by
an expert is possible.
Technical details
Voltage supply
24 V AC (± 20 %) and
15…36 V DC
15…36 V DC
Power consumption
< 1.2 W/ 24 V DC; < 1.8 VA/ 24 V AC
Deviation of humidity
typical ± 2.0 % (20…80 % RH); at + 25 °C, otherwise ± 3.0 %
Data points
Temperature [°C], relative humidity [% RH],
dew point [°C], absolute humidity [g / m3],
mixture ratio [g / kg], enthalpy [kJ / kg]
dew point [°C], absolute humidity [g / m3],
mixture ratio [g / kg], enthalpy [kJ / kg]
Temperature deviation
typically ± 0.2 K at +25 °C
Sensor protection
membrane filter
Measuring range
0...100 % RH (humidity)
-35...+80 °C (temperature)
-35...+80 °C (temperature)
Measuring ranges
–35...+80 °C
0...100 % RH
0...100 % RH
Zero point offset
± 10 % RH (humidity)
± 5 °C (temperature)
± 5 °C (temperature)
Ambient temperature
–30...+70 °C
Medium
clean air and
non-aggressive, non-combustible gases
non-aggressive, non-combustible gases
Bus protocol
Modbus (RTU mode),
address range 0...247 selectable
address range 0...247 selectable
Signal filtering
4 s / 32 s
Electrical connection
0.2 - 1.5 mm², via push-in terminal
Communication
W-Modbus (Wireless Modbus with 2.4 GHz ISM)
Sensor
digital humidity sensor
with integrated temperature sensor,
low hysteresis, high long-term stability
with integrated temperature sensor,
low hysteresis, high long-term stability
Permissible air humidity
< 95 % RH, non-precipitating air
Protection class
III (according to EN 60 730)
Protection type
IP 65 (according to EN 60 529)*
Protection type housing
IP 65
Process connection
endless metal strap with metal tightener,
300 mm, for pipes up to 3 ''
(included in scope of delivery)
300 mm, for pipes up to 3 ''
(included in scope of delivery)
Cable gland
M 20 x 1.5; with strain relief, replaceable,
inner diameter 8 - 13mm
inner diameter 8 - 13mm
Standards
CE conformity according to Radio Directive 2014 / 53 / EU