Specialists in pressure

Multi-range measuring transducers for pressure, differential pressure and volume flow

PREMASGARD 211x / 212x

Efficient, convenient and network-enabled

Elegant appearance, touch-operated interface, large display, and Modbus-compatible

RYMaskon

Multi-funtional duct sensor

For humidity, temperature, pressure, differential pressure and volume flow for monitoring and controlling heating, ventilation and air-conditioning systems

PREMASGARD® 814x-Modbus

Satisfied customers drive our business

An overview of our references

Learn more

Electronic frost protection monitor

2-phase thermostat with continuous and switching output for reliable prevention of frost damages and freezing

THERMASREG® FS-20

Für jede Anwendung die richtige Lösung [Translate]

ALQ-CO2-W LCD

AERASGARD® ALQ-CO2-W LCD

Item No. 1501-7111-7371-200
EAN 4 251325 613222

Maintenance-free on-wall sensor AERASGARD® ALQ - CO2 - W with active/switching output, automatic calibration (can be deactivated), in an impact-resistant plastic housing with quick-locking screws, optionally with/without Display, for determining the CO2 content of the air (0...2000 ppm/0...5000 ppm), the quality in three VOC sensitivity levels (low/ medium/high), the temperature (–35...+80 °C) as well as the relative air humidity (0…100 % r.H). The measuring transducer converts the measured values into a standard signal of 0 -10 V or 4...20 mA (switchable).

The sensor is used in offices, hotels, convention centres, apartments, shops, etc. for the purpose of evaluating the indoor climate. This enables energy-saving room ventilation on an as-needed basis, thereby reducing operating costs and improving well-being.

A long-term stable, digital humidity and temperature sensor guarantees exact measurement results.

The CO2 measurement is performed using an optical NDIR sensor (non-dispersive infra-red technology). The detection range is calibrated for standard applications such as monitoring residential rooms and conference rooms.

The air quality is detected by a VOC sensor (mixed gas sensor for volatile organic substances). This sensor determines the loading of the room air due to contaminated gases such as cigarette smoke, body perspiration, exhaled breathing air, solvent vapours, emissions from building components, etc. With regard to the expected air contamination, low, medium or high VOC sensitivity can be selected.

500,59 € net
Voltage supply 24 V AC/ DC (± 10 %)
Power consumption < 4.8 W/ 24 V DC typical; < 6.8 VA/ 24 V AC typical; peak current 200 mA
Sensor, VOC
VOC sensor (metal oxide) (VOC = volatile organic compounds),
with manual calibration (via zero button),
with automatic calibration (can be deactivated via DIP switches)
Measuring range, VOC 0...100 % air quality; referred to calibrating gas;
multi-range switching (selectable via DIP switches)
VOC sensitivity low, medium, high
Output, VOC 0 -10 V (0 V = clean air, 10 V = polluted air) or 4...20 mA (selectable via DIP switches,
switchpoint can be adjusted from 0...100 % of the output signal)
Measuring accuracy, VOC ± 20 % of final value (referred to calibrating gas)
Service life > 60 months (under normal load conditions)
depending on the type of loading and gas concentration
Measuring range, CO2 multi-range switching (selectable via DIP switches)
0...2000 ppm; 0...5000 ppm
Sensor, CO2
Optical NDIR sensor (non-dispersive infra-red technology),
with manual calibration (via zero button), 
with automatic calibration (can be deactivated via DIP switches)
Output, CO2 0 -10 V or 4...20 mA (selectable via DIP switches)
Measuring accuracy, CO2 typically ± 30 ppm ± 3 % of measured value
Temperature dependence, CO2 ± 5 ppm/ °C or ± 0.5 % of measured value/ °C
(whichever is higher)
Pressure dependence ± 0,13 %/ mm Hg
Gas exchange by diffusion
Relay output
with potential-free changeover contact (24 V / 1 A)
(assignment selectable via DIP switches, switchpoint adjustable)
Response time < 2 minutes
Output
0 -10 V or 4...20 mA, working resistance < 800 Ω
(selectable via DIP switches, selected variant applies for all outputs),
with offset potentiometer (± 10 % of the measuring range)
Ambient temperature –10...+60 °C
Process connection by screws
Protective tube stainless steel V2A (1.4301), Ø 16 mm, NL = 55 mm
Electrical connection 0.14 - 1.5 mm² via terminal screws
Housing plastic, UV-stabilised,
material polyamide, 30 % glass-globe reinforced,
with quick-locking screws
(slotted/ Phillips head - combination),
colour traffic white (similar to RAL 9016),
housing cover for display is transparent !
Housing dimensions 126 x 90 x 50 mm (Tyr 2)
Cable gland M 16 x 1.5; including strain relief,
exchangeable
Long-term stability < 2 % in 15 years
Protection class III (according to EN 60 730)
Protection type IP 65 (according to EN 60 529)
Standards CE conformity,
electromagnetic compatibility according to EN 61326,
according to EMC Directive 2014/ 30/ EU
Display three-line display with illumination, cutout approx. 70 x 40 mm (W x H),
for displaying actual humidity, actual temperature, air quality and / or the actual CO2 content

S+S Regeltechnik - Benefits to the power of five

Learn more

S+S Regeltechnik News

Exhibition Newsshow all

 

Light + Building 2020 – S+S Regeltechnik will be there
27.09. - 02.10.2020

Hall 9.1 | Booth A84
Be our guest at the world's leading trade fair for light, design and intelligent...
more

Overview of all exhibition dates

Product Newsshow all

 

THERMASGARD® TM65-Modbus -T3 - Calibratable immersion, screw-in or duct temperature measuring transducer

Patented high-quality product (patented immersion sensor, DE 10 2012 017 500.0) – basic device with...
more

 

PREMASGARD® 211x, 212x and 212x-SD - Compact and flexible specialists in pressure