Efficient, convenient and network-enabled

Elegant appearance, touch-operated interface, large display, and Modbus-compatible

RYMaskon

Satisfied customers drive our business

An overview of our references

Learn more

Good room climate is measurable!

Active and Modbus capable room sensors for temperature, humidity and CO2 now also for in-wall installation!

AERASGARD® FSCO2

All quite relative

Pressure measuring transducer for gaseous and liquid media in cost-efficient Standard version for 0 to 16 bar

PREMASGARD® SHD-SD

VOC in focus

Room and duct sensors for detection of mixed gases in cost-efficient Standard versions

AERASGARD® RLQ-SD

Für jede Anwendung die richtige Lösung [Translate]

RLQ-CO2-W DISPLAY

AERASGARD® RLQ-CO2-W DISPLAY

Item No. 1501-61B1-7321-200
EAN 4 251325 613260

The maintenance-free microprocessor-controlled room sensor AERASGARD® RLQ-CO2-W with automatic and manual calibration is used for detecting the overall room climate. It measures CO2 within a range of 0...2000 ppm or 0...5000 ppm, air quality (VOC) in one of three sensitivity levels that can be selected LOW  /  MEDIUM (default)  /  HIGH, temperature within a range of 0...+50°C as well as relative ambient humidity of 0...100 %  r.H. The measured values are converted into standard signals of 0 -10 V oder 4...20 mA ( selectable via DIP switches). As an option, the measured values can be shown continuously in the illuminated display.

Elegant enclosure made of plastic, with snap-on lid, base with 4-hole attachment, for installation on vertically or horizontally installed in-wall flush boxes, with predetermined breaking point for on-wall cable entry. The relative humidity (% r.H.) quotient of water vapour partial pressure divided by the saturation vapour pressure at the respective gas temperature. A digital, long-term stable sensor used as measuring element for relative air humidity and temperature guarantees exact measurement results. The air quality is determined based on a (VOC) gas mixture sensor. The CO2 content of the air is measured using an optical NDIR sensor (non-dispersive infra-red technology). For 

368,43 € net
Voltage supply 24 V AC ⁄ DC (± 10 %)
Power consumption < 4.4 W ⁄ 24 V DC typical; < 6.4 VA ⁄ 24 V AC typical;
peak current 200 mA
Deviation of humidity typical ± 2 % r. H. (20…80 % r. H. ); at + 25 °C, otherwise ± 3 % r. H.
Sensor, VOC VOC sensor (metal oxide) with automatic calibration
(VOC = volatile organic compounds)
Measuring range, VOC 0...100 % air quality; referred to calibrating gas;
multi-range switching (selectable via DIP switches)
VOC sensitivity low, medium, high
Output, VOC 0 -10 V (0 V = clean air, 10 V = polluted air) or 4...20 mA (selectable via DIP switches,
switchpoint can be adjusted from 0...100 % of the output signal)
Measuring accuracy, VOC ± 20 % of final value (referred to calibrating gas)
Service life > 60 months (under normal load conditions)
Measuring range, CO2 multi-range switching (selectable via DIP switches)
0...2000 ppm; 0...5000 ppm
Sensor, CO2 optical NDIR sensor (non-dispersive infra-red technology)
with automatic and manual calibration
Output, CO2 0 -10 V or 4...20 mA (selectable via DIP switches)
Measuring accuracy, CO2 ± 30 ppm ± 3 % of measured value
Temperature dependence, CO2 ± 5 ppm ⁄ °C or ± 0.5 % of measured value ⁄ °C
(whichever is higher)
Pressure dependence ± 0,13 % ⁄ mm Hg
Gas exchange by diffusion
Relay output with potential-free changeover contact 24 V (assignment selectable via DIP switches)
Warm up time approx. 1 hour
Response time < 2 minutes
Output 0 -10 V or 4...20 mA (selectable via DIP switches,
selected variant applies for all outputs), working resistance < 800 Ω
Output 0 -10 V or 4...20 mA (selectable via DIP switches,
selected variant applies for all outputs), working resistance < 800 Ω
Ambient temperature 0...+50 °C
Electrical connection 0.14 - 1.5 mm² via terminal screws
Enclosure plastic, material ABS,
colour pure white (similar to RAL 9010)
Dimensions 98 x 98 x 33 mm (Baldur 2)
Installation wall mounting or on in-wall flush box, Ø 55 mm,
base with 4 holes, for attachment to vertically or
horizontally installed in-wall flush boxes for rear cable entry,
with predetermined breaking point for cable entry
from top ⁄ bottom in case of plain on-wall installation
Long-term stability < 2 % in 15 years
Protection class III (according to EN 60 730)
Protection type IP 30 (according to EN 60 529)
Standards CE conformity, electromagnetic compatibility
according to EN 61 326, EMC Directive 2014 ⁄ 30 ⁄ EU,
Low Voltage Directive 2014 ⁄ 35 ⁄ EU
Display display with illumination, two line, cutout approx. 36 x 15 mm
(W x H), for displaying actual humidity, actual temperature,
air quality and / or the actual CO2 content

S+S Regeltechnik - Benefits to the power of five

Learn more

S+S Regeltechnik News

Exhibition Newsshow all

 

ISH Messe Frankfurt – S+S Regeltechnik looks forward to meeting you!
10. - 15.03.2019

Stand 10.3 A71
At the ISH, the world's leading trade fair for "The Bathroom Experience,...
more

Overview of all exhibition dates

Product Newsshow all

 

Multi-functional duct sensor for monitoring and control of heating, ventilation and air-conditioning systems

This bus capable and calibratable pressure measuring transducer enables the control of differential...
more

 

Good room climate is measurable! - AERASGARD® FSCO2 ⁄ FSTM-CO2 ⁄ FSFTM-CO2-Modbus