Multi-range measuring transducers for pressure, differential pressure and volume flow

PREMASGARD 211x / 212x

Efficient, convenient and network-enabled

Elegant appearance, touch-operated interface, large display, and Modbus-compatible

RYMaskon

Multi-funtional duct sensor

For humidity, temperature, pressure, differential pressure and volume flow for monitoring and controlling heating, ventilation and air-conditioning systems

PREMASGARD® 814x-Modbus

Satisfied customers drive our business

An overview of our references

Learn more

Electronic frost protection monitor

2-phase thermostat with continuous and switching output for reliable prevention of frost damages and freezing

THERMASREG® FS-20

Für jede Anwendung die richtige Lösung [Translate]

Duct CO2 sensor

AERASGARD® KCO2

Patented quality product  (patent no. DE 10 2014 010 719.1)

The maintenance-free microprocessor-controlled duct sensor AERASGARD® KLQ - SD with automatic calibration, housing with snap-on lid, is used for determining the air quality based on a mixed gas sensor/VOC sensor. The measuring signals are converted into standard signals of 0 -10 V.

The maintenance-free microprocessor-controlled duct sensor AERASGARD® KLQ - W with automatic and manual calibration, housing with quick-locking screws, is used for determining the air quality or based on a mixed gas sensor/VOC sensor. The measurement signals are converted into standard signals of 0 -10 V or 4...20 mA.

It is used

- For air quality measurement in offices, hotels, meeting rooms and convention centres, apartments, stores, and restaurants, etc.
- For quantitative evaluation of room air pollution with contaminating gases (cigarette smoke, body perspiration, exhaled breathing air, solvent vapours, emissions from building members and cleaning agents)
- For adjustable sensitivity regarding the maximum air contamination to be expected
- For room ventilation as-needed, enabled by air changes only taking place when air is polluted while conserving energy at the same time.

The sensor's service life depends on the type of burden and gas concentration and is more than 60 months under normal load conditions. The new design allows you to choose between three sensitivity ranges that are adjusted using DIP switches, giving you three measuring ranges: LOW for low, MEDIUM (default) for medium, and HIGH for high VOC sensitivity. VOC is the abbreviation for volatile organic compounds. According to the definition by the World Health Organization WHO, VOC are organic substances with a boiling range from +60 to +250 °C. Examples of VOCs include compounds of the substance groups alkanes /  alkenes, aromatic compounds, terpenes, halogenated hydrocarbons, esters, aldehydes, and ketones. There is a large number of naturally occurring VOCs, some of which are also released into the atmosphere in substantial quantities, e.g. terpenes and isoprene from forests.

CO2: 0...2000ppm / 5000ppm switchable, 
Output: 0-10V / 4...20mA switchable, with Changeover contact

Type Kommunikation Equipment Display CO2 measuring range 1. Temperature range Arbeitsdruck PN max. Buttons Cable connection Colour Control Function Housing Colour Housing_material Kommunikation Measuring range relative humidity Messbereiche CO2 Movement Output Output type Printing Prozessanschluß (SW) Rod length Rohr Ø DN Schutzart(Filter) Sensor-Toleranz Feuchte Sleeve length Temperature-measuring range for insertion length Channels Sensor VOC measuring range Free cable length Housing name Cable material Measuring range pressure Item No. Price
KCO2-W change over contact 5000 ppm CO2 1501-3140-7301-200 261,38 €
KCO2-W LCD change over contact 5000 ppm CO2 1501-3140-7321-200 304,76 €
KCO2-SD-U - 5000 ppm CO2 1501-3160-1001-200 216,89 €

S+S Regeltechnik - Benefits to the power of five

Learn more

S+S Regeltechnik News

Exhibition Newsshow all

Swiss Bau 2020 – S+S Regeltechnik will be there
14.01. - 18.01.2020

Hall 1.2 / Booth B22
Be our guest at the largest construction fair in Switzerland from January 14 to...
more

Overview of all exhibition dates

Product Newsshow all

 

THERMASGARD® TM65-Modbus -T3 - Calibratable immersion, screw-in or duct temperature measuring transducer

Patented high-quality product (patented immersion sensor, DE 10 2012 017 500.0) – basic device with...
more

 

PREMASGARD® 211x, 212x and 212x-SD - Compact and flexible specialists in pressure

These calibratable compact sensors from S+S can manage up to eight switchable measuring ranges from...
more

Exhibition News

SWISS BAU | Basel | 14. – 18. 01. 2020 | (Hall 1.2 / Booth B22)

more

Newsletter Subscription

Stay always informed about our products and news from S+S Regeltechnik